Note: Ingredients listed on restricted chemical lists
EC/CAS
7440-48-4
Name of the chemical
Cobalt, Metall (2020/217)
Concentration
N/A
EC/CAS
7440-47-3
Name of the chemical
Chromium; chromic acid and its salts
Concentration
N/A
General Information
Revision date
2017-07-31
Product name
Dentsply Austenal Laser Weld Wire
Product Synonyms
S GHS AUS EN
1.2.1 Relevant identified uses
Crown and bridge and / or partial dental appliances
Icons in SDS
Company Information
company name
Dentsply (Australia) Pty Ltd
e-mail address of the competent person responsible for the Safety Data Sheet
clientservices@dentsplysirona.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H317, H334, H351, H412
Hazard statements
Code
Statements
H317
May cause an allergic skin reaction
H334
May cause allergy or asthma symptoms or breathing difficulties if inhaled
H351
Suspected of causing cancer
H412
Harmful to aquatic life with long lasting effects
Section 2
2.1 Classification of the substance or mixture
HAZARDOUS CHEMICAL. NON-DANGEROUS GOODS. According to the WHS Regulations and the ADG Code. CHEMWATCH HAZARD RATINGS Min Max Flammability 0 Toxicity 1 0 = Minimum Body Contact 1 1 = Low 2 = Moderate Reactivity 2 3 = High Chronic 2 4 = Extreme Poisons Schedule Not Applicable
Classifications
1] Respiratory Sensitizer Category 1, Skin Sensitizer Category 1, Carcinogenicity Category 2, Acute Aquatic Hazard Category 3, Chronic Aquatic Hazard Category 3 Legend: 1. Classified by Chemwatch; 2. Classification drawn from HSIS ; 3. Classification drawn from EC Directive 1272/2008 - Annex VI
Signal word
DANGER
Hazard statements
H334 May cause allergy or asthma symptoms or breathing difficulties if inhaled. H317 May cause an allergic skin reaction. H351 Suspected of causing cancer. H412 Harmful to aquatic life with long lasting effects.
Prevention
P201 Obtain special instructions before use. P261 Avoid breathing dust/fumes. P280 Wear protective gloves/protective clothing/eye protection/face protection. P281 Use personal protective equipment as required.
Response
P304+P340 IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing. P308+P313 IF exposed or concerned: Get medical advice/attention. P342+P311 If experiencing respiratory symptoms: Call a POISON CENTER or doctor/physician. P363 Wash contaminated clothing before reuse.
Storage
P405 Store locked up.
Disposal
P501 Dispose of contents/container in accordance with local regulations.