Note: Ingredients listed on restricted chemical lists
EC/CAS
7439-92-1
Name of the chemical
Blei, massiv: [Partikeldurchmesser ≥ 1 mm]
Concentration
N/A
EC/CAS
7732-18-5
Name of the chemical
Water, distilled, conductivity or of similar purity H2O
Concentration
N/A
General Information
Revision date
2005-04-04
Product name
Storage Battery, Wet
Product Synonyms
Lead/Acid Battery
Chemical name
Liquid content - sulfuric acid
1.2.1 Relevant identified uses
Electric Storage Battery
Manufacturer Name
Delphi Energy and Chassis Systems
Emergency telephone
INFOTRAC 1-800-535-5053 (domestic); 352-323-3500 (international
Icons in SDS
Company Information
company name
Delphi Energy and Chassis Systems
Section 2
SECTION 2: Hazards identification
Emergency Overview: Danger! Explosive gases. Poison causes severe burns. Wet Storage Battery is a manufactured article composed of lead and acid encased in polypropylene, sealed and vented with a flame arrestor to reduce flashback potential. The case color varies. These batteries contain dilute sulfuric acid, a corrosive substance, and may expel explosive gases. Routes of Entry: Skin: Yes Eye: Yes Inhalation: Yes Ingestion: Yes Acute/Chronic Health Effects: Skin: Sulfuric acid mists or liquid irritates the skin and may cause chemical burns. Severity depends on acid concentration and duration of contact. Eyes: Sulfuric acid mists or liquid irritates the eyes and may cause chemical burns. Severity depends on acid concentration and duration of contact. Scarring of the cornea is possible. Inhalation: Sulfuric acid mists irritate the nose and throat and may cause respiratory difficulty. Ingestion: Sulfuric acid mists or liquid irritates the mucous membrane and may cause chemical burns. Repeated prolonged exposure may damage tooth enamel.
Medical Conditions Generally Aggravated by Exposure
to Sulfuric Acid Pulmonary edema, bronchitis, emphysema, eczema, contact dermatitis, dental erosion and traceobronchitis. SECTION IV