Note: Ingredients listed on restricted chemical lists
EC/CAS
203-473-3/107-21-1
Name of the chemical
Ethane-1,2-diol
Concentration
15-24,5% 5-10%
EC/CAS
203-961-6/112-34-5
Name of the chemical
2-(2-butoxyethoxy)ethanol
Concentration
44-0006 3-5%
EC/CAS
203-489-0/107-41-5
Name of the chemical
2-methylpentane-2,4-diol
Concentration
<0,3%
EC/CAS
200-659-6/67-56-1
Name of the chemical
Methanol
Concentration
3-5%
General Information
Version
30/11/2023
Revision date
2023-11-30
Product name
Fomtec ARC 3x3
1.2.1 Relevant identified uses
Appliance protection
Emergency telephone
+44 1273 289451
Icons in SDS
Company Information
company name
Dafo Fomtec AB
e-mail address of the competent person responsible for the Safety Data Sheet
info@fomtec.com
GHS Information
Signal word
Warning
Hazard Codes
Hazard statements (CLP)
H319, H373, H412
Hazard statements
Code
Statements
H319
Causes serious eye irritation
Section 2
SECTION 2: Hazards identification
According to Regulation (EC) No. 1272/2008 (CLP) Classified
2.1 Classification of the substance or mixture
Eye Irrit. 2; H319, Causes serious eye irritation. STOT RE 2; H373, May cause damage to organs through prolonged or repeated exposure. Aquatic Chronic 3; H412, Harmful to aquatic life with long lasting effects.
2.2 Label elements
Fomtec ARC 3x3
Signal word
Warning
Hazard statements
Causes serious eye irritation. (H319) May cause damage to organs through prolonged or repeated exposure. (H373) Harmful to aquatic life with long lasting effects. (H412)
Precautionary statements
General -
Prevention
Do not breathe vapour/mist. (P260) Avoid release to the environment. (P273) Wear eye protection/protective gloves/protective clothing. (P280)
Response
Get medical advice/attention if you feel unwell. (P314) If eye irritation persists: Get medical advice/attention. (P337+P313)
Disposal
Dispose of contents/container in accordance with local regulation (P501)
Hazardous Ingredients
ethanediol C6 fluorotelomer-based surfactant
2.3 Other hazards
Additional warnings This mixture/product does not contain any substances known to fulfil the criteria for PBT and vPvB classification. This product does not contain any substances considered to be endocrine disruptors in accordance with the criteria set out in Commission Delegated Regulation (EU) 2017/2100 or Commission Regulation (EU) 2018/605.