General Information
Version
1.1 13/10/2008
Revision date
2008-10-13
Product name
Rotair Plus
1.2.1 Relevant identified uses
eo BCom pressor ol
Emergency telephone
+32 3 870 21 05, +44 20 7771 5394, +33 3 44 52 72 27
Icons in SDS
Company Information
company name
contact@airwco.com
e-mail address of the competent person responsible for the Safety Data Sheet
contact@airwco.com
Section 2
Storage
Keep in a cool, dry, well-ventilated place. Use properly labeiled and closeable containers. Avoid direct suntight, heat sources, and strong oxidizing agents. The storage of this product maybe subject to the Control of Pollution (Oil Storage) (England) Regulations. Further guidance maybe obtained from the local environmental agency office. Temperatures 0°C Minimum. 50°C Maximum. Recommended Materials For containers or container linings, use mild steel or high density polyethylene. Unsuitable Materia!s For containers or container linings, avoid PVC.
Further information
Polyethylene containers should not be exposed to high temperatures because of possible risk of distortion. Exposure Limits Substance: [Regulations | JE¥powure Duration expe |Notes Oil mist, mineral EH 40 2005 TWA 5 EH 40 2005 STEL 10 EH 40 2005 EH 40 2005 Health and Safety Executive. EH40; Workplace Exposure Limits Exposure Controls The use of personal protective equipment is only one aspect of an integrated approach to the Control Of Substances Hazardous to Health. The management of Health and Safety at Work Regulations 1992 require employers to identify and evaluate the risks to health and to implement appropriate measures to eliminate or minimise those risks. The choice of personal protective equipment is highly dependent upon local conditions, e.g. exposure to other chemical substances and micro-organisms, thermal hazards (protection from extremes of cold and heat), electrical hazards, mechanical hazards and appropriate degree of manual dexterity required to undertake an activity. Whilst the content of this section may inform the choice of personal protective equipment used, the limitations of any information which can be provided must be fully understood, e.g. personal protective equipment chosen to protect employees from occasional splashes maybe entirely inadequate for activities involving partial or complete immersion.f the levels of oil mist or vapour in air are likely to exceed the occupational exposure standards then consideration should be given to the use of local exhaust ventilation to reduce personal exposure. The choice of personal protective equipment should only be undertaken in the light of a full risk assessment by a suitably qualified competent person ( e.g. a professionally qualified occupational hygienist). Effective protection is only achieved by correctly fitting and well maintained equipment and employers should Version No. 1.1 13/10/2008 Page 3 of 8 Rotair Pius ensure that appropriate training is given. All personal protective equipment should be regularly inspected and replaced if defective. Reference should be made to HSE's publication Methods for the Determination of
Hazardous Ingredients
(MDHS) 84 - Measurement of oi! mist from mineral oil-based metalworking fluids. Measurement of an employee's exposure to oil vapour maybe supplemented through the use of stain tubes. In the first instance, further guidance maybe obtained through HSE's publication 'COSHH - a brief guide to the regulations' (INDG 136(rev1)). Respiratory Protection At standard temperature and pressure, the Occupational Exposure Standard for oil vapour is unlikely to be exceeded. Care should be taken to keep exposures below applicable occupational exposure limits. If this cannot be achieved, use of a respirator fitted with an organic vapour cartridge combined with a particulate pre-filter should be considered. Half masks (EN 149) or valved half masks (EN 405) in combination with type A2 (EN 141) and P2/3 (EN 143) pre-filters maybe considered. Hand Protection Chemical protective gloves are made from a wide range of materials, but there is no single glove material ( or combination of materials) which gives unlimited resistance to any individual or combination of substances or preparations. The extent of the breakthrough time will be affected by a combination of factors which include permeation, penetration, degradation, use pattern ( full immersion, occasional contacts) and how the glove is stored when not in use. . Theoretical maximum levels of protection are seldom achieved in practice and the actual level of protection can be difficult to assess. Effective breakthrough time should be used with care and a margin of safety should be applied. HSE guidance on protective gloves recommends a 75% safety factor to be applied to any figures obtained in a laboratory test. Nitrile gloves may offer relatively long breakthrough times and slow permeation rates. Test data, e.g breakthrough data obtained through test standard EN374-3:1994 are available from reputable equipment suppliers. Personal hygiene is a key element of effective hand care. Gloves must only be worn on clean hands. After using gloves, hands should be washed and dried thoroughly. A non perfumed moisturiser should be applied. Eye Protection Goggles conforming to a minimum standard of EN 166 345B should be considered if there is a possibility of eye contact with the product through splashing. Higher rated eye protection must be considered for highly hazardous operations or work areas. For example, employees involved in metalworking operations such as chipping, grinding or cutting may require additional protection to avert injury from fast moving particles or broken tools. Body Protection Minimise all forms of skin contact. Overalls and shoes with oil resistant soles should be worn. Launder overalls and undergarments regularly. Environmental Exposure Controls ; Minimise release to the environment. An environmental assessment must be made to ensure compliance with loca! environmental legislation. x Colour Light brown. Physical State Liquid at ambient temperature. Odour Characteristic mineral oil. pH Value Data not available. Vapour Pressure Expected to be less than 0.5 Pa at 20°C. Initial Boiling Point Expected to be above 280°C. Solubility in Water Negligible. Density 875 kg/m3 at 15°C. Flash Point 230°C (COC). Flammable Limits - Upper 10%(V/V) (typical). Flammable Limits - Lower 1%(V/V} (typical). Auto-Iignition Temperature Expected to be above 320°C. Kinematic Viscosity 46 mme2/s at 40°C. Evaporation Rate Data not available. Version No. 1.1 13/10/2008 . Page 4 of 8 Rotair Plus Vapour Density (Air=1) Greater than 1. Partition co-efficient, n-octanol/water Log Pow expected to be greater than 6. Pour Point -33°C. Stability Stable. Conditions to Avoid Extremes of temperature and direct sunlight. Materials to Avoid Strong oxidizing agents. Hazardous Decomposition Products Hazardous decomposition products are not expected to form during normal storage. Basis for Assessment Toxicological data have not been determined specifically for this product. Information given is based on a knowledge of the components and the toxicology of similar products. Acute Toxicity - Oral LD50 expected to be > 2000 mg/kg. Acute Toxicity - Dermal LD50 expected to be > 2000 mg/kg. Acute Toxicity - Inhalation Not considered to be an inhalation hazard under normal conditions of use. Eye Irritation Expected to be slightly irritating. * Skin Irritation Expected to be slightly irritating. Respiratory Irritation lf mists are inhaled, slight irritation of the respiratory tract may occur. Skin Sensitisation Not expected to be a skin sensitizer. Carcinogenicity Product is based on mineral oils of types shown to be non-carcinogenic in animal skin-painting studies. Other components are not known to be associated with carcinogenic effects. , Mutagenicity Not considered to be a mutagenic hazard. Reproductive Toxicity Not considered to be toxic to reproduction.