Note: Ingredients listed on restricted chemical lists
EC/CAS
64742-70-7
Name of the chemical
Paraffin oils (petroleum), catalytic dewaxed heavy
Concentration
5 - 10
EC/CAS
64742-71-8
Name of the chemical
Paraffin oils (petroleum), catalytic dewaxed light
Concentration
5 - 10
EC/CAS
123-95-5
Name of the chemical
stearic acid, butyl ester
Concentration
3 - 7
EC/CAS
64742-54-7
Name of the chemical
Distillates (petroleum), hydrotreated heavy paraffinic
Concentration
3 - 7
EC/CAS
124-38-9
Name of the chemical
Carbon dioxide CO2
Concentration
1 - 5
EC/CAS
119-36-8
Name of the chemical
Methyl salicylate
Concentration
1 - 5
EC/CAS
64742-65-0
Name of the chemical
Distillates (petroleum), solvent-dewaxed heavy paraffinic
Concentration
0.5 - 1.5
EC/CAS
64742-52-5
Name of the chemical
Distillates (petroleum), hydrotreated heavy naphthenic
Concentration
0.1 - 1
General Information
Version
1.0
Revision date
2026-01-06
Product name
CRC Power Lube Industrial High Performance Lubricant w/ceramic, 11 Wt Oz
supplier name
CRC Industries, Inc
Emergency telephone
1-800-424-9300
Icons in SDS
Company Information
company name
CRC Industries, Inc
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H229, H304
Hazard statements
Code
Statements
H229
Pressurized container: may burst if heated
H304
May be fatal if swallowed and enters airways
Section 2
SECTION 2: Hazards identification
Classification of the substance or mixture GHS US classification Aerosol, Category 1 Extremely flammable aerosol. Pressurized container: may burst if heated Aspiration hazard, Category 1 May be fatal if swallowed and enters airways. Hazardous to the aquatic environment — Acute Hazard, Category 2 Toxic to aquatic life
2.2 Label elements
GHS US labeling
Signal word
Danger
Hazard statements
Extremely flammable aerosol Pressurized container: may burst if heated May be fatal if swallowed and enters airways
Precautionary statements
Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Do not spray on an open flame or other ignition source. Do not pierce or burn, even after use. Do not apply while equipment is energized. Extinguish all flames, pilot lights, and heaters. Vapors will accumulate readily and may ignite. Exposure to high temperature may cause can to burst. Use only outdoors or in a well-ventilated area. Maintain ventilation during use and until all vapors are gone. Open doors and windows or use other means to ensure a fresh air supply during use and while product is drying. If you experience any symptoms listed on this label, increase ventilation or leave the area. If swallowed: Immediately call a poison center or doctor. Do NOT induce vomiting. Store locked up. Protect from sunlight. Do not expose to temperatures exceeding 122 °F (50 °C). Dispose of contents/container in accordance with local/regional/national regulations.
Other hazards which do not result in classification
Static accumulating flammable liquid can become electrostatically charged even in bonded and grounded equipment. Sparks may ignite liquid and vapor. May cause flash fire or explosion.
Ingredient(s) with unknown acute toxicity
No additional information available
2.1 Classification of the substance or mixture
GHS US classification Aerosol, Category 1 Extremely flammable aerosol. Pressurized container: may burst if heated. Aspiration hazard, Category 1 May be fatal if swallowed and enters airways. Hazardous to the aquatic environment — Acute Hazard, Category 2 Toxic to aquatic life.