Note: Ingredients listed on restricted chemical lists
EC/CAS
270-704-2/68476-85-7
Name of the chemical
Petroleum gases, liquefied; Petroleum gas (A complex combination of hydrocarbons produced by the distillation of crude oil. It consists of hydrocarbons having carbon numbers predominantly in the range of C3 through C7 and boiling in the range of approximately - 40 °C to 80 °C.)
Concentration
25 - 50
EC/CAS
265-158-7/64742-55-8
Name of the chemical
Distillates (petroleum), hydrotreated light paraffinic
Concentration
≤1
General Information
Version
1.2
Revision date
2024-06-10
Product name
CCL100 CONTACT CLEANER LUBRICANT
1.2.1 Relevant identified uses
Professional use
supplier name
CRC Industries Europe UK Limited
Emergency telephone
+44 1278 727200
Icons in SDS
Company Information
company name
CRC Industries Europe UK Limited
e-mail address of the competent person responsible for the Safety Data Sheet
hse@crcind.com, hse.uk@crcind.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H222, H229, H304, H411
Hazard statements
Code
Statements
H222
Extremely flammable aerosol
H229
Pressurized container: may burst if heated
H304
May be fatal if swallowed and enters airways
H411
Toxic to aquatic life with long lasting effects
Section 2
SECTION 2: Hazards identification
According to Regulation (EC) No. 1272/2008 (CLP) Classification of the substance or mixture
Adverse physicochemical, human health and environmental effects
Pressurised container: May burst if heated. Extremely flammable aerosol. May be fatal if swallowed and enters airways. Toxic to aquatic life with long lasting effects
Hazard pictograms
GHS02 GHS09
Signal word
Danger
Hazard statements
H222 - Extremely flammable aerosol. H229 - Pressurised container: May burst if heated. H411 - Toxic to aquatic life with long lasting effects.
Precautionary statements
P102 - Keep out of reach of children. P210 - Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P211 - Do not spray on an open flame or other ignition source. P251 - Do not pierce or burn, even after use. P410+P412 - Protect from sunlight. Do not expose to temperatures exceeding 50 °C. P501 - Dispose of contents/container to a hazardous or special waste collection point, in accordance with local, regional, national and/or international regulation.
Supplemental label elements
EUH066 - Repeated exposure may cause skin dryness or cracking.
2.3 Other hazards
Contains no PBT and/or vPvB substances ≥ 0.1% assessed in accordance with REACH Annex XIII
2.1 Classification of the substance or mixture
Classification according to Regulation (EC) No. 1272/2008 [CLP] Aerosol, Category 1 H222;H229 Aspiration hazard, Category 1 H304 Hazardous to the aquatic environment – Chronic Hazard, H411 Category 2 Full text of H- and EUH-statements: see section 16 Adverse physicochemical, human health and environmental effects Pressurised container: May burst if heated. Extremely flammable aerosol. May be fatal if swallowed and enters airways. Toxic to aquatic life with long lasting effects.