Note: Ingredients listed on restricted chemical lists
EC/CAS
75-09-2
Name of the chemical
Methylene chloride
Concentration
10-30
EC/CAS
68476-85-7
Name of the chemical
Petroleum gases, liquefied
Concentration
30-60
General Information
Version
6.1
Revision date
2023-03-10
Product name
CRC(NZ) 8290 On & Off Aerosol Adhesive
Product name
CRC(NZ) 8290 On & Off Aerosol Adhesive
Identification on the label/Trade name
AEROSOLS
Product Synonyms
Not Available
Chemical name
Not Applicable
1.2.1 Relevant identified uses
Application is by spray atomisation from a hand held aerosol pack Use according to manufacturer"s directions
Emergency telephone
+64 800 700 112, +61 3 9573 3188
Icons in SDS
Company Information
company name
CRC Industries
e-mail address of the competent person responsible for the Safety Data Sheet
info.nz@crc.co.nz
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H302, H315, H319, H351, H373
Hazard statements
Code
Statements
H302
Harmful if swallowed
Section 2
SECTION 2: Hazards identification
1272/2008 Classification of the substance or mixture Classification [1] Legend: Determined by Chemwatch using GHS/HSNO criteria Aerosols Category 1, Acute Toxicity (Oral) Category 4, Skin Corrosion/Irritation Category 2, Serious Eye Damage/Eye Irritation Category 2, Carcinogenicity Category 2, Specific Target Organ Toxicity - Repeated Exposure Category 2 Classified by Chemwatch; 2. Classification drawn from CCID EPA NZ; 3. Classification drawn from Regulation (EU) No
Signal word
Danger
Hazard statements
H222+H229 Extremely flammable aerosol. Pressurized container: may burst if heated. H302 Harmful if swallowed. H315 Causes skin irritation. H319 Causes serious eye irritation. H351 Suspected of causing cancer. H373 May cause damage to organs through prolonged or repeated exposure.
Prevention
P201 Obtain special instructions before use. P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P211 Do not spray on an open flame or other ignition source. P251 Do not pierce or burn, even after use.
Response
P308+P313 IF exposed or concerned: Get medical advice/ attention. P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P314 Get medical advice/attention if you feel unwell. P337+P313 If eye irritation persists: Get medical advice/attention.
Storage
P405 Store locked up. P410+P412 Protect from sunlight. Do not expose to temperatures exceeding 50 °C/122 °F.
Disposal
P501 Dispose of contents/container to authorised hazardous or special waste collection point in accordance with any local regulation.
2.1 Classification of the substance or mixture
Category 2, Carcinogenicity Category 2, Specific Target Organ Toxicity - Repeated Exposure Category 2 1. Classified by Chemwatch; 2. Classification drawn from CCID EPA NZ; 3. Classification drawn from Regulation (EU) No Legend: 1272/2008 - Annex VI Determined by Chemwatch 2.1.2A, 6.1D (oral), 6.3A, 6.4A, 6.7B, 6.9B using GHS/HSNO criteria