CRC NF LECTRA-SOLVE PERMASTRAW

CRC INDUSTRIES (AUST) PTY LIMITED

Revision date : 2025-04-03

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.
GHS07
Health risk rating 3
Safety risk rating 4
Environmental risk rating 3

Note: Ingredients listed on restricted chemical lists

EC/CAS

204-696-9/124-38-9

Name of the chemical

Carbon dioxide CO2

Concentration

3 to 8%

General Information

Version

1.1

Revision date

2025-04-03

Product name

CRC NF LECTRA-SOLVE PERMASTRAW

Product Synonyms

1755780 - PRODUCT CODE

1.2.1 Relevant identified uses

AEROSOL DISPENSED ● SOLVENT BASED DEGREASER

supplier name

CRC INDUSTRIES (AUST) PTY LIMITED

Icons in SDS

GHS07 T018

Company Information

company name

CRC INDUSTRIES (AUST) PTY LIMITED

e-mail address of the competent person responsible for the Safety Data Sheet

info.au@crcind.com

GHS Information

Signal word

WARNING

Hazard Codes

Hazard statements (CLP)

H229, H332, H412

Hazard statements

Code

Statements

H229

Pressurized container: may burst if heated

Section 2

SECTION 2: Hazards identification

Classification of the substance or mixture

Health hazards

Acute Toxicity: Inhalation: Category 4 Environmental Hazards Aquatic Toxicity (Chronic): Category 3

Signal word

WARNING

Hazard statements

H229 Pressurized container: may burst if heated. H332 Harmful if inhaled. H412 Harmful to aquatic life with long lasting effects.

Prevention

P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P251 Do not pierce or burn, even after use. P261 Avoid breathing dust/fume/gas/mist/vapours/spray. P271 Use only outdoors or in a well-ventilated area.

Response

P304 + P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing. P312 Call a POISON CENTRE or doctor/physician if you feel unwell.

Storage

P410 + P412 Protect from sunlight. Do not expose to temperatures exceeding 50°C.

Disposal

P501 Dispose of contents/container in accordance with relevant regulations.

Other hazards

No information provided

2.1 Classification of the substance or mixture

CLASSIFIED AS HAZARDOUS ACCORDING TO SAFE WORK AUSTRALIA CRITERIA Physical Hazards Aerosols - Pressurised: Category 3 Health Hazards Acute Toxicity: Inhalation: Category 4 Environmental Hazards Aquatic Toxicity (Chronic): Category 3

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.