Note: Ingredients listed on restricted chemical lists
EC/CAS
123-86-4
Name of the chemical
acetic acid, butyl ester
Concentration
N/A
EC/CAS
822-06-0
Name of the chemical
Hexamethylene diisocyanate
Concentration
N/A
General Information
Revision date
2021-05-06
Product name
DESMODUR N 3580 BA
Chemical name
Aliphatic Polyisocyanate in Organic Solvent
1.2.1 Relevant identified uses
Raw material for coatings, adhesives, sealants, or elastomers in
1.2.2. Uses advised against
Do-It-Yourself Applications, Medical applications
Icons in SDS
Company Information
company name
Covestro LLC
GHS Information
Signal word
Warning
Section 2
2.1 Classification of the substance or mixture
Flammable liquids: Category 3 Acute toxicity (Inhalation): Category 4 Skin sensitisation: Category 1 Specific target organ toxicity - Category 3 (Respiratory system, Central nervous system) single exposure:
Signal word
Warning
Hazard statements
Flammable liquid and vapour. May cause an allergic skin reaction. Harmful if inhaled. May cause respiratory irritation. May cause drowsiness or dizziness.
Prevention
Keep away from heat, sparks, open flames, and hot surfaces. - No smoking Keep container tightly closed. Ground/bond container and receiving equipment. Use explosion-proof electrical, ventilating and lighting equipment. Use only non-sparking tools. Take precautionary measures against static discharge. Avoid breathing dust, mist, gas, vapors or spray. Use only outdoors or in a well-ventilated area. Contaminated work clothing must not be allowed out of the workplace. Wear permeation resistant protective gloves and clothing. Wear eye and face protection.
Response
IF ON SKIN (or hair): Remove/Take off immediately all contaminated clothing. Rinse skin with water/shower. IF INHALED: Remove person to fresh air and keep at rest in a position comfortable for breathing. Call a doctor or emergency medical facility (i.e. 911) if you feel unwell. If skin irritation or rash occurs: Get medical attention. Wash contaminated clothing before reuse. In case of fire: Use dry chemical, carbon dioxide (CO2), foam, or water spray (for large fires) to extinguish.
Storage
Store in a well-ventilated place. Keep container tightly closed. Keep cool. Store locked up.
Disposal
Dispose of contents and container in accordance with existing federal, state, and local environmental control laws.