Note: Ingredients listed on restricted chemical lists
EC/CAS
231-100-4/7439-92-1
Name of the chemical
Blei, massiv: [Partikeldurchmesser ≥ 1 mm]
Concentration
60-80
EC/CAS
231-146-5/7440-36-0
Name of the chemical
Antimony
Concentration
1-5
General Information
Revision date
2011-07-20
Product name
Powerflow Wire 3mm
1.2.1 Relevant identified uses
soldering
Manufacturer Name
Cookson Electronics Assembly
Emergency telephone
+31 (35) 695 5411, +44(0)1483 758400, +31 (35) 694 8451, +44(0)1483 728837
Icons in SDS
Company Information
company name
Cookson Electronics
e-mail address of the competent person responsible for the Safety Data Sheet
shosken@cooksonelectronics.com
Hazard Codes
Hazard statements (CLP)
H300
Hazard statements
Code
Statements
H300
Fatal if swallowed
Section 2
SECTION 2: Hazards identification
Directive 1999/45/EC: The product is not classified as dangerous according to Directive 1999/45/EC and its amendments.
2.1 Classification of the substance or mixture
Not classified. Effects and symptoms Inhalation May be fatal if inhaled. Ingestion : May be fatal if swallowed. Skin contact : Non-irritant to skin. Toxicity data : lead: Warning! Contains lead. Over-exposure signs/symptoms:- blood formation impairment, central nervous system depression May cause harm to the unborn child. Repeated or prolonged exposure to the substance can produce reproductive system damage. Additional warning phrases : Safety data sheet available for professional user on request. See section 11 for more detailed information on health effects and symptoms.