Note: Ingredients listed on restricted chemical lists
General Information
Revision date
2011-06-09
Product name
ALPHA 611 RMA ROSIN FLUX
CAS No.
67-63-0
1.2.1 Relevant identified uses
Specialty assembly materials for the electronics industries
Manufacturer Name
Cookson Electronics
Icons in SDS
Company Information
company name
Cookson Electronics
GHS Information
Signal word
WARNING!
Section 2
SECTION 2: Hazards identification
OSHA Physical state Liquid. OSHA/HCS status : This material is considered hazardous by the OSHA Hazard Communication Standard (29 CFR 1910.1200). Emergency overview WARNING! Flammable liquid. This product contains material(s) that are absorbed through the skin. Harmful in contact with skin and if swallowed. Severely irritating to eyes. Irritating to respiratory system and skin. May cause sensitization by skin contact. Keep away from heat, sparks and flame. Do not breathe vapor or mist. Do not ingest. Do not get in eyes or on skin or clothing. Contains material that may cause target organ damage, based on animal data. Use only with adequate ventilation. Keep container tightly closed and sealed until ready for use. Wash thoroughly after handling.
Principle Routes of Exposure
Dermal contact. Eye contact. Inhalation. Ingestion.
Potential Acute Health Effects
Inhalation Irritating to respiratory system. Ingestion Harmful if swallowed. Can cause target organ damage. Ingestion may cause gastrointestinal irritation and diarrhea. Skin Irritating to skin. Harmful in contact with skin. This product contains material(s) that are absorbed through the skin. Can cause target organ damage. and symptoms similar to those listed under inhalation or ingestion. May cause sensitization by skin contact. Skin inflammation is characterized by itching, scaling, reddening or, occasionally, blistering. Prolonged or repeated contact may cause dermatitis. Once sensitized, a severe allergic reaction may occur when subsequently exposed to very low levels. In the event of any complaints or symptoms, avoid further exposure. Persons with a history of skin sensitization problems should not be employed in any process in which this product is used. Eyes Severely irritating to eyes. Risk of serious damage to eyes. Adverse symptoms may include the following: redness, itching, swelling, pain Potential chronic health effects
Potential chronic health
Contains material that can cause target organ damage. Adverse symptoms may include the following: Rosin/Resin: May cause allergic skin reactions with repeated exposure. Prolonged inhalation of fumes may cause respiratory sensitization. Target organs : Contains material which may cause damage to the following organs: kidneys, lungs, liver, upper respiratory tract, skin, central nervous system (CNS), eye, lens or cornea. Carcinogenicity : Not classified or listed by IARC, NTP, OSHA, EU and ACGIH. Mutagenicity : No conclusive data is available to indicate product or any component present at greater than 0.1% may cause heritable genetic effects.
Teratogenic Effects
No evidence. Developmental effects : No conclusive data is available to indicate product or any component present at greater than 0.1% may cause developmental abnormalities. Fertility effects : No conclusive data is available to indicate product or any component present at greater than 0.1% may impair fertility. Medical conditions Pre-existing skin and digestive disorders and disorders involving any other target organs aggravated by over- mentioned in this MSDS as being at risk may be aggravated by over-exposure to this exposure product. Persons with a history of skin sensitization problems should not be employed in any process in which this product is used.