Note: Ingredients listed on restricted chemical lists
EC/CAS
7732-18-5
Name of the chemical
Water, distilled, conductivity or of similar purity H2O
Concentration
N/A
General Information
Revision date
2014-01-02
Product name
Redi-Stor Conductivity Probe Storage Solution
supplier name
Control Company
Icons in SDS
Company Information
company name
Control Company
e-mail address of the competent person responsible for the Safety Data Sheet
sales@control3.com
Section 2
SECTION 2: Hazards identification
OSHA Hazard Classification: Has a 96'F Flash Point but does not support combustion. Ref: 49 CFR 173.120(a)(3) for DOT exemption from "Flammable Liquid" classification. Routes of Entry: Skin, eyes, Inhalation, ingestion Chemical Interactions: Avoid contact with all oxidizing agents, acids, acid chlorides, acid anhydrides, halogens, aluminum and aluminum alloys.
Medical Conditions Generally Aggravated by Exposure
No information. Human Threshold Response Data Odor Threshold: Not established Irritation Threshold: Not established
Hazard categories
Classifications and Ratings Health Fire Pressure Reactivity Reference 49 CFR 171.8, Immediate Yes No OSHA 29 CFR 1910.1200 and Delayed No SARA 302/311/312/313. HMIS Hazard Ratings: Health 1 Fire 1 Instability 0 Other B (Goggles, gloves) NFPA 704 Hazard Ratings: Health 1 Flammability 1 Reactivity 0 Special NA
Hazard statements
Least 0 Slight 1 Moderate 2 High 3 Extreme 4 Notice: HMIS and NFPA ratings involve the subjective evaluation of the hazardous aspects of individual components, and can differ between preparers. They are intended and useful only as a rapid, general identification of the approximate magnitude of the specific hazards rated. Immediate (Acute) Health Effects Inhalation Toxicity: Harmful if inhaled or swallowed. Inhalation Irritation: High concentrations or prolonged exposure can cause headaches, dizziness and nausea . Skin Contact: Skin contact may cause irritation from dehydration and de-fatting of the skin. Skin Absorption: No immediate responses. Eye Contact Liquid and vapor cause eye irritation, tearing and a burning sensation. Ingestion Irritation: Irritating. Ingestion Toxicity: Almost non toxic. See Sec. 11. Acute Target Organ Toxicity: Kidneys, liver, central nervous system.
Potential chronic health
Carcinogenicity: Rated A3 = Confirmed Animal carcinogen with Unknown Relevance to Humans. Reproductive and Developmental Toxicity: Mutagenic effects were noted in animal studies. Sensitization: None known. Inhalation: Prolonged or repeated exposure may cause more severe irritation. May cause pulmonary edema (fluid build-up in lungs). See also Inhalation entry above. Skin Contact: Prolonged or repeated skin exposure may cause dermatitis. Skin Absorption: Chronic exposure may cause liver damage. Ingestion: Chronic ingestion unlikely. See Acute entry above. Can lead to liver damage. General : Prolonged or repeated exposure may cause all acute toxic symptoms described above. Chronic Target Organ Toxicity: Liver Supplemental Health Hazard Information: No additional health information available. Product Name(s): Redi-Stor™ Conductivity Probe Storage Solution Date: January 2014 Product Number(s): 4170