Health risk rating 1
Safety risk rating 1
Environmental risk rating 1

Note: Ingredients listed on restricted chemical lists

EC/CAS

1313-13-9

Name of the chemical

Manganese dioxide

Concentration

15-40

Listed in

EC/CAS

7791-03-9

Name of the chemical

Lithium Perchlorate

Concentration

-1,5

Listed in

EC/CAS

7439-93-2

Name of the chemical

Lithium

Concentration

1-5

Listed in

EC/CAS

7782-42-5

Name of the chemical

Graphite

Concentration

1-4

General Information

Revision date

2016-09-29

Product name

Non-Rechargeable Alkaline Button Cell

Manufacturer Name

Conrad Electronic SE

Icons in SDS

Company Information

company name

Conrad Electronic SE

Section 2

SECTION 2: Hazards identification

OSHA Boiling Point KOH agua solution = 140 degree Celsius Specific Gravity (H2O = 1) MnO2 = 4.4, Zn = 7.1, KOH = 2.0 Vapor Pressure (mm Indium) KOH aqua solution = 0.2mm Indium at 20 degree Celsius Melting Point MnO2 - decomposes at 535 degree Celsius Zn = 420 degree Celsius, KOH aqua = -35 degree Celsius Vapor Density (Air -1) N/A Evaporation Rate (Butyl Acetate = 1) N/A Solubility in Water KOH – complete Appearance and Color MnO2 is a black powder, Graphite is also a black powder, Zinc is a silver metal. KOH aqua is a colorless liquid with stimulated odor. 4. First Aid Measures In case of skin contact with content of battery, flush immediately with water. For eye contact, flush with copious amount of water for 10 minutes. If imitation persists, get medical help. 5. Fire Fighting Measures Flash point (Method used) Incombustible Flammable Limits LBL UEL Not Applicable Extinguishing Media -DO- Special Fire Fighting Procedure -DO- Unusual Fire and Explosion Hazards -DO- 6. Accidental Release Measures

Principle Routes of Exposure

Inhalation: YES Skin: YES Ingestion: YES Inhalation: YES Skin: YES Ingestion: YES

Health hazards

Acute and Chronic) These chemicals are contained in a sealed can. Risk of exposure occurs, only if battery is mechanically or electrically abused. The most likely risk is acute exposure when a call vents KOH is caustic alkali and attack the skin and eyes.Contact of electrolyte with skin and eyes should be avoided. Cardnogenicity NTP: None IARC Monographs: None OSHA Regulated: None Signs and Symptoms of exposure KOH can cause chemical burn upon contact with skin. (Acute and Chronic) These chemicals are contained in a sealed can. Risk of exposure occurs, only if battery is mechanically or electrically abused. The most likely risk is acute exposure when a call vents KOH is caustic alkali and attack the skin and eyes. Contact of electrolyte with skin and eyes should be avoided. Carinogenicity NTP: None IARC Monographs: None OSHA Regulated: None Signs and Symptoms of exposure KOH can cause chemical burn upon contact with skin.

Medical Conditions Generally Aggravated by Exposure

An acute exposure will not generally aggravate any medical help. Emergency and First Aid Procedures In case of skin contact with content of battery, flush immediately with water. For eye contact, flush with copious amount of water for 10 minutes. If imitation persists, get medicla help. 7. Handling and Storage Steps to be taken in case material is released or spilled Wipe out by wet duster Waste Disposal Method General abandonment Precautions to be taken in handling and storing Avoid mechanical or electrical abuse. Other precaustions Do not short circuit, charge or dispose of in fire. Battery may explode or leak. 8. Exposure Controls/Personal Protection Flash point (Method used) Incombustible Flammable Limits LBL UEL N/A Extnguishing Media N/A Special Fire Figting Procedure N/A Unusual Fire and Explosion Hazards N/A 9. Physical and Chemical Properties Compiled with 98/101/EEC & 91/157/EEC Specification (%) 1) Mercury Content < 0.0001 2) Cadmium Content < 0.001 3) Lead Content < 0.001 10. Stability and Reactivity Stability stable Conditions to avoid do not short-circuit, charge or dispose of in fire Incompatibility (Materials to Avoid) N/A Hazardous polymerization will not occur Hazardous Decomposition or byproducts N/A An acute exposure will not generally aggravate any medical help. Emergency and First Aid Procedures In case of skin contact with content of battery, flush immediately with water. For eye contact, flush with copious amount of water for 10 minutes. If imitation persists, get medical help.

Disposal

Condition Waste Disposal Method General abandonment. 13. Regulatory Information  Battery should be kept away from the reach of children.  If the battery is accidentally swallowed, s/he should consult the doctor immediately.  If the battery is used in the applications for children, the battery compartment should be capable of bombardment.  If the applications have alternate power supply, the integrated circuit can only use primary battery instead of secondary battery.  The battery should be placed correctly for the positive and negative terminals.  Please do not try to heat, recharge or use other mean to recycle the primary battery.  Please do not heat or throw the battery in fire or try to dismantle the battery by yourself.  Please do not short circuit the battery.  Please do not use electrical welding to weld the positive and negative terminals of battery directly.  After the use of applications, please switch off the power supply.  If the applications will not be used for a long period of time, the battery should be removed.  Please change all the batteries at the same time instead of changing some of them only. Newly added batteries should not be mixed with the used ones as they have different chemical systems, grade and brand, etc. Otherwise, some batteries may be subject to leakage due to the extreme use.

Further information

Products are according to IEC60086-2000 and 98/101/EC standard. Do not short circuit, charge or dispose of in fire. Battery may explode or leak. 15. Transportation We further declare the battery terminals are protect and the cargo is in all repects in proper condition for transport. Alkaline batteries are considered to be „dry cell“ batteries and are not subject to dangerous goods regulation for the purpose of transportation by the International Civil Aviation Organization (ICAO), the International Air Transport Association (IATA) or the International Maritime Dangerous Goods regulations (IMDG). Alkaline batteries offered for transport are not subject to other provisions of these Regulations if they meet the following : „Cells and batteries are separated so as to prevent short circuits and are packed in strong packaging.“ „Referring the captioned shipment of battery, such battery have been packed in inner packing in such a manner as to effectively prevent from short circuits and the movements which could lead to short circuits.“ Steps to be taken in case material is released or spilled: Wipe out by wet duster. Avoid mechanical or electrical abuse. 1. Product & Company Identification Coin type Lithium Manganese Dioxide Non-Rechargeable Battery Product: Model: CR2016, CR2025, CR2032 Manufacturer: Conrad Electronic SE Nominal voltage: 3 V Address: Klaus-Conrad-Str. 1, D-92240 Hirschau Telephone: +49 (0) 9604 / 40 - 8988 Date of Issue 29.09.2016

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.