Note: Ingredients listed on restricted chemical lists
General Information
Revision date
2016-09-29
Product name
Non-Rechargeable Alkaline Button Cell
Manufacturer Name
Conrad Electronic SE
Icons in SDS
Company Information
company name
Conrad Electronic SE
Section 2
SECTION 2: Hazards identification
OSHA Boiling Point KOH agua solution = 140 degree Celsius Specific Gravity (H2O = 1) MnO2 = 4.4, Zn = 7.1, KOH = 2.0 Vapor Pressure (mm Indium) KOH aqua solution = 0.2mm Indium at 20 degree Celsius Melting Point MnO2 - decomposes at 535 degree Celsius Zn = 420 degree Celsius, KOH aqua = -35 degree Celsius Vapor Density (Air -1) N/A Evaporation Rate (Butyl Acetate = 1) N/A Solubility in Water KOH – complete Appearance and Color MnO2 is a black powder, Graphite is also a black powder, Zinc is a silver metal. KOH aqua is a colorless liquid with stimulated odor. 4. First Aid Measures In case of skin contact with content of battery, flush immediately with water. For eye contact, flush with copious amount of water for 10 minutes. If imitation persists, get medical help. 5. Fire Fighting Measures Flash point (Method used) Incombustible Flammable Limits LBL UEL Not Applicable Extinguishing Media -DO- Special Fire Fighting Procedure -DO- Unusual Fire and Explosion Hazards -DO- 6. Accidental Release Measures
Principle Routes of Exposure
Inhalation: YES Skin: YES Ingestion: YES Inhalation: YES Skin: YES Ingestion: YES
Health hazards
Acute and Chronic) These chemicals are contained in a sealed can. Risk of exposure occurs, only if battery is mechanically or electrically abused. The most likely risk is acute exposure when a call vents KOH is caustic alkali and attack the skin and eyes.Contact of electrolyte with skin and eyes should be avoided. Cardnogenicity NTP: None IARC Monographs: None OSHA Regulated: None Signs and Symptoms of exposure KOH can cause chemical burn upon contact with skin. (Acute and Chronic) These chemicals are contained in a sealed can. Risk of exposure occurs, only if battery is mechanically or electrically abused. The most likely risk is acute exposure when a call vents KOH is caustic alkali and attack the skin and eyes. Contact of electrolyte with skin and eyes should be avoided. Carinogenicity NTP: None IARC Monographs: None OSHA Regulated: None Signs and Symptoms of exposure KOH can cause chemical burn upon contact with skin.
Medical Conditions Generally Aggravated by Exposure
An acute exposure will not generally aggravate any medical help. Emergency and First Aid Procedures In case of skin contact with content of battery, flush immediately with water. For eye contact, flush with copious amount of water for 10 minutes. If imitation persists, get medicla help. 7. Handling and Storage Steps to be taken in case material is released or spilled Wipe out by wet duster Waste Disposal Method General abandonment Precautions to be taken in handling and storing Avoid mechanical or electrical abuse. Other precaustions Do not short circuit, charge or dispose of in fire. Battery may explode or leak. 8. Exposure Controls/Personal Protection Flash point (Method used) Incombustible Flammable Limits LBL UEL N/A Extnguishing Media N/A Special Fire Figting Procedure N/A Unusual Fire and Explosion Hazards N/A 9. Physical and Chemical Properties Compiled with 98/101/EEC & 91/157/EEC Specification (%) 1) Mercury Content < 0.0001 2) Cadmium Content < 0.001 3) Lead Content < 0.001 10. Stability and Reactivity Stability stable Conditions to avoid do not short-circuit, charge or dispose of in fire Incompatibility (Materials to Avoid) N/A Hazardous polymerization will not occur Hazardous Decomposition or byproducts N/A An acute exposure will not generally aggravate any medical help. Emergency and First Aid Procedures In case of skin contact with content of battery, flush immediately with water. For eye contact, flush with copious amount of water for 10 minutes. If imitation persists, get medical help.
Disposal
Condition Waste Disposal Method General abandonment. 13. Regulatory Information Battery should be kept away from the reach of children. If the battery is accidentally swallowed, s/he should consult the doctor immediately. If the battery is used in the applications for children, the battery compartment should be capable of bombardment. If the applications have alternate power supply, the integrated circuit can only use primary battery instead of secondary battery. The battery should be placed correctly for the positive and negative terminals. Please do not try to heat, recharge or use other mean to recycle the primary battery. Please do not heat or throw the battery in fire or try to dismantle the battery by yourself. Please do not short circuit the battery. Please do not use electrical welding to weld the positive and negative terminals of battery directly. After the use of applications, please switch off the power supply. If the applications will not be used for a long period of time, the battery should be removed. Please change all the batteries at the same time instead of changing some of them only. Newly added batteries should not be mixed with the used ones as they have different chemical systems, grade and brand, etc. Otherwise, some batteries may be subject to leakage due to the extreme use.
Further information
Products are according to IEC60086-2000 and 98/101/EC standard. Do not short circuit, charge or dispose of in fire. Battery may explode or leak. 15. Transportation We further declare the battery terminals are protect and the cargo is in all repects in proper condition for transport. Alkaline batteries are considered to be „dry cell“ batteries and are not subject to dangerous goods regulation for the purpose of transportation by the International Civil Aviation Organization (ICAO), the International Air Transport Association (IATA) or the International Maritime Dangerous Goods regulations (IMDG). Alkaline batteries offered for transport are not subject to other provisions of these Regulations if they meet the following : „Cells and batteries are separated so as to prevent short circuits and are packed in strong packaging.“ „Referring the captioned shipment of battery, such battery have been packed in inner packing in such a manner as to effectively prevent from short circuits and the movements which could lead to short circuits.“ Steps to be taken in case material is released or spilled: Wipe out by wet duster. Avoid mechanical or electrical abuse. 1. Product & Company Identification Coin type Lithium Manganese Dioxide Non-Rechargeable Battery Product: Model: CR2016, CR2025, CR2032 Manufacturer: Conrad Electronic SE Nominal voltage: 3 V Address: Klaus-Conrad-Str. 1, D-92240 Hirschau Telephone: +49 (0) 9604 / 40 - 8988 Date of Issue 29.09.2016