Note: Ingredients listed on restricted chemical lists
EC/CAS
7439-92-1
Name of the chemical
Blei, massiv: [Partikeldurchmesser ≥ 1 mm]
Concentration
N/A
EC/CAS
7440-36-0
Name of the chemical
Antimony
Concentration
N/A
EC/CAS
7440-38-2
Name of the chemical
Arsenic (As)
Concentration
N/A
General Information
Revision date
2014-03-18
Product name
LEAD ACID BATTERY
Emergency telephone
CONCORDE BATTERY CORPORATION
Icons in SDS
Company Information
company name
CONCORDE BATTERY CORPORATION
Section 2
SECTION 2: Hazards identification
Do not open battery. Avoid contact with internal components. Internal components include lead and liquid electrolyte. Signs and 1. Acute Electrolyte - Electrolyte is corrosive and contact may cause skin irritation and chemical burns. Electrolyte causes Symptoms of severe irritation and burns of eyes, nose and throat. Ingestion can cause severe burns and vomiting. Exposure Lead - Direct skin or eye contact may cause local irritation. Inhalation or ingestion of lead dust or fumes may result in headache, nausea, vomiting, abdominal spasms, fatigue, sleep disturbances, weight loss, anemia and leg, arm and joint pain. Electrolyte - Repeated contact with sulfuric acid and battery electrolyte fluid may cause drying of the skin that may result in irritations, dermatitis, and skin burns. Repeated exposure to sulfuric acid mist may cause erosion of teeth, chronic eye irritation and / or chronic inflammation of the nose, throat, and lungs. 2. Subchronic Lead - Prolonged exposure may cause central nervous system damage, gastrointestinal disturbances, anemia, irritability, metallic taste, insomnia, wrist- and Chronic drop, kidney dysfunction and reproductive system disturbances. Pregnant women should be protected from excessive exposure to prevent lead from
Potential health effects
crossing the placental barrier and causing infant neurological disorders. California Proposition 65 Warning: Batteries and other related parts contain lead. Battery posts, terminals, and related accessories contain lead and lead compounds, chemicals known to the State of California to cause cancer and reproductive harm. Batteries also contain other chemicals known to the State of California to cause cancer. Wash hands after handling.
Medical Conditions Generally Aggravated by Exposure
If battery is broken or material is spilled, then persons with the following medical conditions must take precautions: pulmonary edema, bronchitis, emphysema, dental erosion and tracheobronchitis. Routes of Entry Inhalation - YES Eye Contact- YES Ingestion – YES Skin Contact - YES Chemical(s) Listed as Carcinogen or potential Proposition 65 - YES National Toxicology Program - I.A.R.C. OSHA - NO Carcinogen YES Monographs - YES