Note: Ingredients listed on restricted chemical lists
EC/CAS
215-540-4/12179-04-3
Name of the chemical
Disodium tetraborate pentahydrate
Concentration
<1%
EC/CAS
278-928-2/78491-02-8
Name of the chemical
1-[1,3-bis(hydroxymethyl)-2,5-dioxoimidazolidin-4-yl]-1,3-bis(hydroxymethyl)urea; Diazolidinylurea
Concentration
<1%
General Information
Version
GB - EN
Revision date
2016-05-12
Product name
UC30 BioSonic General Purpose Ultrasonic Cleaning Solution
1.2.1 Relevant identified uses
for dental use only
Manufacturer Name
Coltène/Whaledent Inc
Emergency telephone
+1 (330) 916 8800, +1 (330) 916 7077, +49 (7345) 805 0, +49 (7345) 805 201
Icons in SDS
Company Information
company name
Coltène/Whaledent Inc
e-mail address of the competent person responsible for the Safety Data Sheet
info.us@coltene.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H318, H360FD
Hazard statements
Code
Statements
H318
Causes serious eye damage
Section 2
SECTION 2: Hazards identification
Regulation (EC) No. 1272/2008 Classification of the substance or mixture
Hazard categories
Serious eye damage/eye irritation: Eye Dam. 1 Hazard Statements Causes serious eye damage This product is not required to be classified as a Reproductive Toxicant when sold within the European Union
Hazardous Ingredients
Alkyl Polyglycosides
Signal word
Danger
Hazard statements
H318 Causes serious eye damage.
Precautionary statements
P280 Wear protective gloves/protective clothing/eye protection/face protection. P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P310 Immediately call a doctor. P405 Store locked up.
Special rules for supplemental label elements for certain mixtures
EUH208
Contains
Diazolidinyl urea. May produce an allergic reaction
2.1 Classification of the substance or mixture
Regulation (EC) No. 1272/2008 Hazard categories: Serious eye damage/eye irritation: Eye Dam. 1 Hazard Statements: Causes serious eye damage. This product is not required to be classified as a Reproductive Toxicant when sold within the European Union . The borax concentration is below classification thresholds according the Regulation (EC) No 1272/2008. The classification H360FD applies for markets where national law has not established a cutoff limit for Borax .