Note: Ingredients listed on restricted chemical lists
EC/CAS
203-492-7/107-46-0
Name of the chemical
Hexamethyldisiloxane
Concentration
≥ 95.0 - < 99.0 %
EC/CAS
208-764-9/541-02-6
Name of the chemical
D5
Concentration
≥ 0.1 - < 1.0 %
EC/CAS
203-497-4/107-51-7
Name of the chemical
Octamethyltrisiloxane
Concentration
≥1.0-<10.0%
General Information
Version
02
Revision date
2023-01-09
Product name
Appeel Medical Adhesive Remover Spray
1.2.1 Relevant identified uses
To ease the removal of adhesive appliances (self- adhesives, such as dressings and tapes; or similar, including hydrocolloids and ostomy devices)
Emergency telephone
+44 1628 850100
Icons in SDS
Company Information
company name
CliniMed Ltd.
e-mail address of the competent person responsible for the Safety Data Sheet
QARA@clinimed.co.uk
GHS Information
Signal word
DANGER
Hazard Codes
Hazard statements (CLP)
H223, H225, H400, H410, H411
Hazard statements
Code
Statements
H223
Flammable aerosol
Section 2
SECTION 2: Hazards identification
Regulation (EC) No. 1272/2008 The products listed in SECTION 1.1 Product Identifier are regulated as medical devices in accordance with Medical Device Directive (EU) 93/42/EEC, as amended, and with Medical Device Regulation (EU) 2017/745 and labelled accordingly. They have been assessed and are supplied with a Safety Data Sheet in accordance with Regulation
Signal word
DANGER WARNING
Hazard statements
H225 Highly flammable liquid and vapour. H410 Very toxic to aquatic life with long-lasting H223 Flammable aerosol. effects. P210 Keep away from heat, hot surfaces, sparks, P210 Keep away from heat, hot surfaces, open flames, and other ignition sources – no sparks, open flames, and other ignition smoking. sources – no smoking. P261 Avoid breathing spray. P211 Do not spray on an open flame or other ignition source. P271 Use only outdoors or in a well-ventilated P251 Pressurized container: do not pierce area. or burn, even after use.
Precautionary statements
P273 Avoid release to the environment P370 In case of fire: Use dry sand, dry chemical, or alcohol-resistant foam to extinguish. P410 Protect from sunlight. + P378 In case of fire: Use water spray, alcohol- P412 Do not expose to temperatures resistant foam, dry chemical, or carbon dioxide to exceeding 50° C / 122° F. extinguish. P391 Collect spillage.
2.3 Other hazards
Vapours may form explosive mixture with air. Static-accumulating flammable liquid. The products listed in SECTION 1.1 Product identifier contain decamethylcyclopentasiloxane that has been identified by the Member State Committee of European Chemicals Agency as fulfilling the vPvB criteria laid down in Annex XIII
2.1 Classification of the substance or mixture
Substance or mixture Flammable liquids, Category 2 H225 Highly flammable liquid and vapour Short-term (acute) aquatic hazard, Category 1 H400 Very toxic to aquatic life Long-term (chronic) aquatic hazard, Category 2 H411 Toxic to aquatic life with long-lasting effects Flammable aerosol: Category 2