General Information
Version
2.6
Revision date
2021-12-08
Product name
Sulfur Calibration Standard
CAS No.
544-40-1
Emergency telephone
1.832.813.4984, 800.424.9300, 703.527.3887, +612 9186 1132, +32.14.584545, +32.14583516, +55.19.3467.1600, +(54)-1159839431
Icons in SDS
Company Information
company name
Chevron Phillips Chemical Company LP
e-mail address of the competent person responsible for the Safety Data Sheet
SDS@CPChem.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H227, H315, H319, H331, H336
Hazard statements
Code
Statements
H227
Combustible liquid
Section 2
SECTION 2: Hazards identification
2.1 Classification of the substance or mixture
This product has been classified in accordance with the hazard communication standard 29 CFR : Flammable liquids, Category 4 Acute toxicity, Category 3, Inhalation Skin irritation, Category 2 Eye irritation, Category 2A Specific target organ toxicity - single exposure, Category 3, Central nervous system
Signal word
Danger
Hazard statements
H227: Combustible liquid. H315: Causes skin irritation. H319: Causes serious eye irritation. H331: Toxic if inhaled. H336: May cause drowsiness or dizziness.
Prevention
P210 Keep away from heat/ sparks/ open flames/ hot surfaces. No smoking. P261 Avoid breathing dust/fume/gas/mist/vapors/spray. P264 Wash skin thoroughly after handling. P280 Wear protective gloves/ eye protection/ face protection.
Response
P302 + P352 IF ON SKIN: Wash with plenty of soap and water. P304 + P340 + P311 IF INHALED: Remove person to fresh air and keep comfortable for breathing. Call a POISON CENTER/ doctor. P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P332 + P313 If skin irritation occurs: Get medical advice/ attention. P337 + P313 If eye irritation persists: Get medical advice/ attention. P362 Take off contaminated clothing and wash before reuse. P370 + P378 In case of fire: Use dry sand, dry chemical or alcohol-resistant foam to extinguish.
Storage
P403 + P233 Store in a well-ventilated place. Keep container tightly closed. P403 + P235 Store in a well-ventilated place. Keep cool.
Disposal
P501 Dispose of contents/ container to an approved waste disposal plant. Carcinogenicity: IARC No ingredient of this product present at levels greater than or equal to 0.1% is identified as probable, possible or confirmed human carcinogen by IARC. NTP No ingredient of this product present at levels greater than or equal to 0.1% is identified as a known or anticipated carcinogen by NTP.