Note: Ingredients listed on restricted chemical lists
EC/CAS
822-06-0
Name of the chemical
Hexamethylene diisocyanate
Concentration
N/A
General Information
Revision date
2014-07-17
Product name
Rhino ArmaFloor 500 AU B-Side
Product Synonyms
1800 039 008
Icons in SDS
Company Information
company name
Rhino Linings (Rhino Linings Australasia)
e-mail address of the competent person responsible for the Safety Data Sheet
info@rhinolinings.com.au
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H227, H317, H332, H334
Hazard statements
Code
Statements
H227
Combustible liquid
Section 2
2.1 Classification of the substance or mixture
HAZARDOUS CHEMICAL. NON-DANGEROUS GOODS. According to the WHS Regulations and the ADG Code. COMBUSTIBLE LIQUID, regulated for storage purposes only CHEMWATCH HAZARD RATINGS Min Max Flammability 1 Toxicity 2 0 = Minimum Body Contact 1 1 = Low 2 = Moderate Reactivity 1 3 = High Chronic 2 4 = Extreme Poisons Schedule S6 [1] Flammable Liquid Category 4, Acute Toxicity (Inhalation) Category 4, Skin Sensitizer Category 1, Respiratory Sensitizer Category 1 Legend: 1. Classified by Chemwatch; 2. Classification drawn from HSIS; 3. Classification drawn from Regulation (EU) No 1272/2008 - Annex VI
Signal word
DANGER
Hazard statements
H227 Combustible liquid. H332 Harmful if inhaled. H317 May cause an allergic skin reaction. H334 May cause allergy or asthma symptoms or breathing difficulties if inhaled.
Prevention
P210 Keep away from heat/sparks/open flames/hot surfaces. - No smoking. P261 Avoid breathing mist/vapours/spray. P271 Use only outdoors or in a well-ventilated area. P280 Wear protective gloves/protective clothing/eye protection/face protection.
Response
P304+P340 IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing. P342+P311 If experiencing respiratory symptoms: Call a POISON CENTER or doctor/physician. P363 Wash contaminated clothing before reuse. P370+P378 In case of fire: Use alcohol resistant foam or normal protein foam for extinction.
Storage
P403+P235 Store in a well-ventilated place. Keep cool.
Disposal
P501 Dispose of contents/container in accordance with local regulations.