General Information
Revision date
2011-06-27
Product name
BuildSecure
Chemical name
Silyl terminated polyether
1.2.1 Relevant identified uses
Moisture cure sealant
Icons in SDS
Company Information
company name
CHEM LINK PRODUCTS LLC
Section 2
SECTION 2: Hazards identification
HMIG Health 1 EMERGENCY OVERVIEW Flammability 0 Reactivity 0 Human Effects and Symptoms of Exposure Protective Equipment B Routes of Entry — Dermal contact, Eye. Acute Eye Contact — Direct contact can cause severe irritation. Acute Skin Contact — Direct contact may cause slight irritation. Skin Absorption — Not Toxic. Acute Inhalation — Product is extremely low in volatility and therefore not likely to pose a problem from inhalation. Acute Ingestion — May be harmful if ingested, not a likely route of entry.
Potential chronic health
of exposure — Repeated or prolonged direct contact to the eyes may cause chemical burns. Repeated or prolonged direct contact to the skin may cause a dermatitis.
Medical Conditions Generally Aggravated by Exposure
Preexisting skin and eye disorders may be aggravated by direct contact to this product. Carcinogenicity — There are no components in this product that are listed as a carcinogen by NTP IARC ACGIH or