GHS02 GHS05 GHS07
Health risk rating 3
Safety risk rating 5
Environmental risk rating 1

Note: Ingredients listed on restricted chemical lists

EC/CAS

7647-01-0

Name of the chemical

Hydrochloric acid

Concentration

0.04N

General Information

Product name

OxiSelect Ascorbic Acid Assay Kit (FRASC)

1.2.1 Relevant identified uses

Laboratory Research Reagents

Emergency telephone

Cell Biolabs, Inc

Icons in SDS

GHS02 GHS05 GHS07

Company Information

company name

Cell Biolabs, Inc

e-mail address of the competent person responsible for the Safety Data Sheet

info@cellbiolabs.com

GHS Information

Signal word

Danger

Hazard Codes

Hazard statements (CLP)

H226, H290, H302, H314, H315, H318, H319, H335

Hazard statements

Code

Statements

H226

Flammable liquid and vapour

Section 2

SECTION 2: Hazards identification

Colorimetric Probe (10X) (Part No. 286001): Two 1 mL tubes

2.1 Classification of the substance or mixture

Corrosive to metals, Category 1 (H290) Skin corrosion, Category 1B (H314) Skin irritation, Category 2 (H315) Serious eye damage, Category 1 (H318) Eye irritation, Category 2A (H319) Specific target organ toxicity - single exposure, Category 3, Respiratory system (H335) Corrosive to metals, Category 1 (H290) Acute toxicity, Oral, Category 4 (H302) Skin irritation, Category 2 (H315) Serious eye damage, Category 1 (H318) Flammable liquids, Category 3 (H226) Skin corrosion, Category 1A (H314) Serious eye damage, Category 1 (H318)

Signal word

Danger Danger Danger

Hazard statements

May be corrosive to metals (H290), Causes severe skin burns and eye damage (H314), Causes skin irritation (H315), Causes serious eye irritation (H319), May cause respiratory irritation (H335). May be corrosive to metals (H290), Harmful if swallowed (H302), Causes skin irritation (H315), Causes serious eye damage (H318). Flammable liquid and vapor (H226), Causes severe skin burns and eye damage (H314).

Precautionary statements

Avoid breathing dust/fume/gas/mist/vaoprs/spray (P261), Wash skin thoroughly after handling (P264), Use only outdoors or in a well-ventilated area (P271), Wear protective gloves/protective clothing/eye protection/face protection (P280), IF SWALLOWED: rinse mouth. Do NOT induce vomiting (P301 + P330 + P331), IF ON SKIN: wash with plenty of soap and water (P302 + P352), IF ON SKIN (or hair): take off immediately all contaminated clothing Rinse skin with water/shower (P303 + P361 + P353), IF INHALED: remove person to fresh air and keep comforable for breathing. Immediately call a POISON CENTER/doctor. (P304 + P340 + P310), IF IN EYES: rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER / doctor (P305 + P351 + P338 + P310), Call a POISON CENTER or doctor/physician if you feel unwell (P312), If skin irritation occurs: Get medical advice/attention (P332 + P313), If eye irritation persists: get medical advice/attention (P337 + P313), Take off contaminated clothing and wash before reuse (P362), Absorb spillage to prevent material damage (P390), Store in a well-ventilated place. Keep container tightly closed (P403 + P233), Store locked up (P405), Store in corrosive resistant stainless steel container with a resistant inner liner (P406), Dispose of contents/container to an approved waste disposal plant (P501). Iron Chloride Solution (10X) (Part No. 286002): Two 1 mL tubes Keep only in original container (P234), Wash skin thoroughly after handling (P264), Do not eat, drink, or smoke when using this product (P270), Wear protective gloves/protective clothing/eye protection/face protection (P280), IF SWALLOWED: Call a POISON CENTER/doctor if you feel unwell. Rinse mouth. (P301 + P312 + P330), IF ON SKIN: wash with plenty of soap and water (P302 + P352), IF IN EYES: rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER / doctor (P305 + P351 + P338 + P310), If skin irritation occurs: Get medical advice/attention (P332 + P313), Take off contaminated clothing and wash before reuse (P362), Absorb spillage to prevent material damage (P390), Store in corrosive resistant stainless steel container with a resistant inner liner (P406), Dispose of contents/container to an approved waste disposal plant (P501). Assay Buffer (5X) (Part No. 286004): Two 25 mL bottles Keep away from heat/sparks/open flames/hot surfaces. No smoking (P210), Keep container tightly closed (P233), Ground/bond container adn receiving equipment (P240), Use explosion-proof electrical/ventilating/lighting/equipment (P241), Use only non-sparking tools (P242), Take precautionary measures against static discharge (P243), Wash skin thoroughly after handling (P264), Wear protective gloves/protective clothing/eye protection/face protection (P280), IF SWALLOWED: rinse mouth. Do NOT induce vomiting (P301 + P330 + P331), IF ON SKIN (or hair): take off immediately all contaminated clothing Rinse skin with water/shower (P303 + P361 + P353), IF INHALED: remove person to fresh air and keep comforable for breathing. Immediately call a POISON CENTER / doctor (P304 + P340 + P310), IF IN EYES: rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER / doctor (P305 + P351 + P338 + P310), Wash contaminated clothing before reuse (P363), In case of fire: use dry sand, dry chemical or alcohol-resistant foam to extinguish (P370 + P378), Store in a well-ventilated place. Keep cool (P403 + P235), Store locked up (P405), Dispose of contents/container to an approved waste disposal plant (P501).

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.