General Information
Revision date
2015-10-07
Product name
Hydraulic fluid
1.2.2. Uses advised against
For specific application advice see appropriate Technical Data Sheet or consult our
supplier name
Castrol Industrial North America, Inc
Emergency telephone
1(800) 424-9300
Icons in SDS
Company Information
company name
Castrol Industrial North America, Inc
GHS Information
Signal word
Panger
Hazard Codes
Hazard statements (CLP)
H304
Hazard statements
Code
Statements
H304
May be fatal if swallowed and enters airways
Section 2
SECTION 2: Hazards identification
Aspiration hazard
Category 1
Signal word
Panger
Hazard statements
May be fatal if swallowed and enters airways.
Prevention
Not applicable.
Response
IF SWALLOWED: Immediately call a POISON CENTER or physician. Do NOT induce vomiting.
Storage
Store locked up.
Disposal
Dispose of contents and container in accordance with all local, regional, national and international regulations.
2.3 Other hazards
Defatting to the skin. Note: High Pressure Applications Injections through the skin resulting from contact with the product at high pressure constitute a major medical emergency. See 'Notes to physician' under First-Aid Measures, Section 4 of this Safety Data Sheet. [ Product name Brayco Micronic 882 Product code 451700-US03 Page: 1/9 Version 1.01 Date of issue 10/07/2015. Format US Language ENGLISH