Note: Ingredients listed on restricted chemical lists
EC/CAS
67-66-3
Name of the chemical
Chloroform
Concentration
1.7
General Information
Version
4.0
Revision date
2024-06-14
Product name
1% Chloroform in acetone-D₆
1.2.2. Uses advised against
No additional information available
supplier name
Cambridge Isotope Laboratories, Inc
Emergency telephone
1-703-741-5970
Icons in SDS
Company Information
company name
Cambridge Isotope Laboratories, Inc
e-mail address of the competent person responsible for the Safety Data Sheet
cilsales@isotope.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H225, H319, H336, H351, H373
Hazard statements
Code
Statements
H225
Highly Flammable liquid and vapour
Section 2
SECTION 2: Hazards identification
Classification (GHS-US)
Flammable liquids Category 2 H225 Highly flammable liquid and vapor Serious eye damage/eye irritation Category 2 H319 Causes serious eye irritation Carcinogenicity Category 2 H351 Suspected of causing cancer (Dermal, Inhalation, oral) Specific target organ toxicity – Single exposure, Category 3, Narcosis H336 May cause drowsiness or dizziness Specific target organ toxicity (repeated exposure) Category 2 H373 May cause damage to organs (central nervous system, kidneys, liver) through prolonged or repeated exposure (Dermal, Inhalation, oral)
Hazard statements
see section 16 : H225 - Highly flammable liquid and vapor H319 - Causes serious eye irritation H336 - May cause drowsiness or dizziness H351 - Suspected of causing cancer (Dermal, Inhalation, oral) H373 - May cause damage to organs (central nervous system, kidneys, liver) through prolonged or repeated exposure (Dermal, Inhalation, oral)
2.2 Label elements
GHS US labeling
Signal word
Danger
Precautionary statements
P201 - Obtain special instructions before use. P202 - Do not handle until all safety precautions have been read and understood. P210 - Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. heat, hot surfaces, open flames, sparks P233 - Keep container tightly closed. P240 - Ground/Bond container and receiving equipment. P241 - Use explosion-proof electrical, lighting, ventilating equipment. P242 - Use only non-sparking tools. P243 - Take precautionary measures against static discharge. P260 - Do not breathe dust, fume, gas, mist, spray, vapors. P261 - Avoid breathing dust, fume, gas, mist, spray, vapors. P264 - Wash hands, forearms and face thoroughly after handling. P271 - Use only outdoors or in a well-ventilated area. P280 - Wear protective clothing, protective gloves. P303+P361+P353 - If on skin (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower. P304+P340 - If inhaled: Remove person to fresh air and keep comfortable for breathing. P305+P351+P338 - IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P308+P313 - If exposed or concerned: Get medical advice/attention. P312 - Call a doctor, a POISON CENTER if you feel unwell. P314 - Get medical advice/attention if you feel unwell. P337+P313 - If eye irritation persists: Get medical advice/attention. P370+P378 - In case of fire: Use alcohol resistant foam, carbon dioxide (CO2), dry extinguishing powder to extinguish. P403+P233 - Store in a well-ventilated place. Keep container tightly closed. P403+P235 - Store in a well-ventilated place. Keep cool. P405 - Store locked up. P501 - Dispose of contents/container to hazardous or special waste collection point, in accordance with local, regional, national and/or international regulation.
Other hazards which do not result in classification
No additional information available
Ingredient(s) with unknown acute toxicity
Not applicable