Note: Ingredients listed on restricted chemical lists
EC/CAS
7727-37-9
Name of the chemical
Nitrogen N2
Concentration
78.36 -99.9983
EC/CAS
75-28-5
Name of the chemical
iso-Butan, enthält 0,1% Butadien
Concentration
0.0001-19.49
EC/CAS
630-08-0
Name of the chemical
Carbon monoxide
Concentration
0.0001-1
General Information
Revision date
2016-07-27
Product name
Oxygen (0.0001 - 19.49%), Carbon Monoxide (0.0005 - 0.9%), Hydrogen Sulfide (0.001 - 0.25%), Isobutane (0.0001 - 1.0%) in Nitrogen
Product Synonyms
Oxygen (0.0001 - 19.49%), Carbon Monoxide
Icons in SDS
Company Information
company name
Calgaz, division of Airgas USA LLC
e-mail address of the competent person responsible for the Safety Data Sheet
info@Calgaz.com
GHS Information
Signal word
Warning
Hazard Codes
Hazard statements (CLP)
H280
Hazard statements
Code
Statements
H280
Contains gas under pressure; may explode if heated
Section 2
Classification (GHS-US)
Gases under pressure H280 Compressed gas
Hazard statements
see section 16 : H280 - Contains gas under pressure; may explode if heated CGA-HG10 - Asphyxiating even with adequate oxygen CGA-HG16 - Extended exposure to gas reduces the ability to smell sulfides
2.2 Label elements
GHS-US labeling
Hazard pictograms
GHS04
Signal word
Warning
Precautionary statements
P202 - Do not handle until all safety precautions have been read and understood P260 - Do not breathe gas P271 - Use only outdoors or in a well-ventilated area P280 - Wear eye protection, face protection, protective gloves, protective clothing P304+P340 - If inhaled: Remove person to fresh air and keep comfortable for breathing P308+P313 - If exposed or concerned: Get medical advice/attention P403 - Store in a well-ventilated place P501 - Dispose of contents/container in accordance with local/regional/national/international regulations CGA-PG02 - Protect from sunlight when ambient temperature exceeds 52°C/125 °F CGA-PG05 - Use a back flow preventive device in the piping CGA-PG06 - Close valve after each use and when empty CGA-PG10 - Use only with equipment rated for cylinder pressure CGA-PG14 - Approach suspected leak area with caution CGA-PG21 - Open valve slowly CGA-PG29 - Do not depend on odor to detect presence of gas
Other hazards which do not result in classification
This product contains a chemical asphyxiant. 10/03/2016 EN (English US) SDS ID: 50200 Page 1 2.4.
Ingredient(s) with unknown acute toxicity