Note: Ingredients listed on restricted chemical lists
EC/CAS
7727-37-9
Name of the chemical
Nitrogen N2
Concentration
82.41
EC/CAS
106-97-8
Name of the chemical
n-Butan, enthält 0,1% Butadien
Concentration
1
EC/CAS
75-28-5
Name of the chemical
iso-Butan, enthält 0,1% Butadien
Concentration
1
EC/CAS
110-54-3
Name of the chemical
n-Hexan (790/2009)
Concentration
0.03
General Information
Revision date
2015-05-18
Product name
10% Methane, 2.5% Ethane, 2.5% Propane, 1.0% iso-Butane, 1.0% n-Butane, 0.25% iso- Pentane, 0.25% n-Pentane, 0.03% Hexane, 0.03% 2-Methyl pentane, 0.03% 3-Methyl pentane in balance Nitrogen
Product Synonyms
Nitrogen
Emergency telephone
1-800-424-9300
Icons in SDS
Company Information
company name
Calgaz, division of Airgas USA LLC
e-mail address of the competent person responsible for the Safety Data Sheet
info@Calgaz.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H220, H280
Hazard statements
Code
Statements
H220
Extremely flammable gas
H280
Contains gas under pressure; may explode if heated
Section 2
Classification (GHS-US)
Flammable gases Category 1 H220 Gases under pressure Compressed gas H280
Hazard statements
see section 16 : H220 - Extremely flammable gas H280 - Contains gas under pressure; may explode if heated OSHA-H01 - May displace oxygen and cause rapid suffocation CGA-HG04 - May form explosive mixtures with air
2.2 Label elements
GHS-US labeling
Hazard pictograms
GHS02 GHS04
Signal word
Danger
Precautionary statements
P202 - Do not handle until all safety precautions have been read and understood P210 - Keep away from heat, hot surfaces, open flames, sparks. - No smoking P271 - Use only outdoors or in a well-ventilated area P280 - Wear eye protection, face protection, protective gloves, protective clothing P304+P340 - If inhaled: Remove person to fresh air and keep comfortable for breathing P308+P313 - If exposed or concerned: Get medical advice/attention P377 - Leaking gas fire: Do not extinguish, unless leak can be stopped safely P381 - Eliminate all ignition sources if safe to do so P403 - Store in a well-ventilated place P501 - Dispose of contents/container in accordance with local/regional/national/international regulations CGA-PG02 - Protect from sunlight when ambient temperature exceeds 52°C/125 °F CGA-PG05 - Use a back flow preventive device in the piping 10/03/2016 EN (English US) SDS ID: 50107 Page 1 CGA-PG06 - Close valve after each use and when empty CGA-PG10 - Use only with equipment rated for cylinder pressure CGA-PG14 - Approach suspected leak area with caution CGA-PG21 - Open valve slowly
2.3 Other hazards
No additional information available 2.4.
Ingredient(s) with unknown acute toxicity
Not applicable