Note: Ingredients listed on restricted chemical lists
EC/CAS
8052-41-3
Name of the chemical
Stoddard Solvent; Naphtha (petroleum), hydrodesulfurized heavy
Concentration
>=42-<43
General Information
Revision date
2018-06-21
Product name
BYK-320
1.2.1 Relevant identified uses
Leveling Additive
Emergency telephone
203-265-2086; CHEMTREC 1-800-424-9300 / +1 703-527- number
Icons in SDS
Company Information
company name
BYK USA Inc
e-mail address of the competent person responsible for the Safety Data Sheet
BRIEF.BYK.NAFTA@altana.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H226, H304, H336
Hazard statements
Code
Statements
H226
Flammable liquid and vapour
Section 2
2.1 Classification of the substance or mixture
Flammable liquids : Category 3 Specific target organ toxicity : Category 3 (Central nervous system) - single exposure
Aspiration hazard
Category 1
Signal word
Danger
Hazard statements
H226 Flammable liquid and vapour. H304 May be fatal if swallowed and enters airways. H336 May cause drowsiness or dizziness.
Prevention
P210 Keep away from heat/sparks/open flames/hot surfaces. No smoking. P233 Keep container tightly closed. P240 Ground/bond container and receiving equipment. P241 Use explosion-proof electrical/ ventilating/ lighting equipment. P242 Use only non-sparking tools. P243 Take precautionary measures against static discharge. P261 Avoid breathing dust/ fume/ gas/ mist/ vapours/ spray. P271 Use only outdoors or in a well-ventilated area. P280 Wear protective gloves/ eye protection/ face protection.
Response
P301 + P310 IF SWALLOWED: Immediately call a POISON CENTER/doctor. P303 + P361 + P353 IF ON SKIN (or hair): Remove/ Take off immediately all contaminated clothing. Rinse skin with water/ shower. P304 + P340 + P312 IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing. Call a POISON CENTER or doctor/ physician if you feel unwell. P331 Do NOT induce vomiting. P370 + P378 In case of fire: Use dry sand, dry chemical or alcohol-resistant foam for extinction.
Storage
P403 + P233 Store in a well-ventilated place. Keep container tightly closed. P403 + P235 Store in a well-ventilated place. Keep cool. P405 Store locked up.
Disposal
P501 Dispose of contents/ container to an approved waste disposal plant.
2.3 Other hazards