DMA; Marine Gas Oil; MGO; Gas Oil; F76; DMAXX; DMALS

Bomin Deutschland GmbH & Co. KG

Revision date : 2014-01-22

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.
Health risk rating 1
Safety risk rating 1
Environmental risk rating 1

Note: Ingredients listed on restricted chemical lists

EC/CAS

68334-30-5

Name of the chemical

Fuels, diesel, except if the full refining history is known and it can be shown that the substance from which it is produced is not a carcinogen

Concentration

N/A

EC/CAS

269-822-7

Name of the chemical

Fuels, diesel, except if the full refining history is known and it can be shown that the substance from which it is produced is not a carcinogen

Concentration

N/A

General Information

Revision date

2014-01-22

Product name

DMA; Marine Gas Oil; MGO; Gas Oil; F76; DMAXX; DMALS

CAS No.

68334-30-5

Emergency telephone

+49 (0)180 100 31 28

Icons in SDS

Company Information

company name

Bomin Deutschland GmbH & Co. KG

e-mail address of the competent person responsible for the Safety Data Sheet

mail@bomin.com

Section 2

SECTION 2: Hazards identification

No. 1272/2008 This preparation is classified as hazardous according to EG No. 1272/2008 (GHS). This preparation is classified as hazardous according to EG No. 67/548/EWG or 1999/45/EG. Hazards characteristic May cause cancer. Very toxic to aquatic organisms may cause long-term adverse effects in the aquatic environment. Informations pertaining to special dangers for human and environment Repeated exposure may cause skin dryness or cracking. People who suffer from skin sensitazion problems, asthma, allergies, chronic or recurring respiratory illnesses should not be deployed in any process using this preparation. Inhalation of vapour or mist may cause irritation of the respiratory system. This material is combustible and can be ignited by heat, sparks, flames, or other sources of ignition (e.g. static electricity, pilot lights, or mechanical/electrical equipment). Vapours of flammable solvents can accumulate in the gas phase of closed container, especially during heat treatment. ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.