Note: Ingredients listed on restricted chemical lists
EC/CAS
931-334-3/7440-44-0
Name of the chemical
Carbon black
Concentration
10-20%
EC/CAS
215-108-5/1302-78-9
Name of the chemical
bentonite
Concentration
N/A
General Information
Version
This document is based on the SDS provided by Lamothe-Abiet and has been adapted by Blue H2O Filtration
Revision date
2022-02-21
Product name
Greenfine Must/Mix/Rose/Intense/X-Press/Nature
Manufacturer Name
Lamothe-Abiet
Icons in SDS
Company Information
company name
Blue H2O Filtration
e-mail address of the competent person responsible for the Safety Data Sheet
contact@lamothe-abiet.com, info@blueh2o.com.au
GHS Information
Signal word
None
Section 2
SECTION 2: Hazards identification
2.1 Classification of the substance or mixture
Not hazardous
Hazard pictograms
None
Signal word
None
Hazard statements
None
Precautionary statements
None
Additional information
None.
2.2 Label elements
None.
2.3 Other hazards
Skin contact: May cause irritation on prolonged contact. Eye contact: May cause eye irritation upon direct contact. Ingestion: Excessive ingestion of highly concentrated yeast powder could lead to intestinal discomfort (e.g. diarrhea, bloating, cramping, etc.). Following inhalation: In some cases, repeated exposure may lead to allergic sensitization based on the exposure level, duration and susceptibility of the individual. Subsequent chronic or acute exposure in sensitized persons may cause allergic reaction within minutes or a delayed effect, or a mixture of both. Typical symptoms are respiratory irritation, breathlessness, coughing, tightness and difficulty breathing. The product contains less than 1% w/w RCS (respirable crystalline silica) as determined by the SWERF method. The respirable crystalline silica content can be measured using the "Size-Weighted Respirable Fraction - SWERF" method. All details about the SWERF method are available at www.crystallinesilica.eu. Depending on the handling and use (grinding, drying, bagging), airborne respirable dust may be generated. Dust contains respirable crystalline silica. Prolonged and or massive inhalation of respirable crystalline silica dust may cause lung fibrosis, commonly referred to as silicosis. Principal symptoms of silicosis are cough and breathlessness. Occupational exposure to respirable dust should be monitored and controlled. The product should be handled using methods and techniques that minimize or eliminate dust generation. The substance does not meet the criteria for PBT or vPvB substance.