Note: Ingredients listed on restricted chemical lists
EC/CAS
206-019-2/288-32-4
Name of the chemical
Imidazol (2015/1221)
Concentration
100%
General Information
Revision date
2015-07-16
Product name
Ready-to-Use Ni QR Agarose Beads Buffer Kit
CAS No.
288-32-4
Manufacturer Name
BioVision, Inc
Icons in SDS
Company Information
company name
BioVision, Inc
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H302, H314, H360
Hazard statements
Code
Statements
H302
Harmful if swallowed
Section 2
SECTION 2: Hazards identification
NFPA Rating Component Description Volume Safety Information EZLys™ Mammalian-Bacterial Protein Proprietary Reagent 20 ml See below Extraction Reagent Ni QR Agarose Loading Proprietary Buffer 120 ml No hazards Ni QR Agarose Elution Buffer Proprietary Buffer (contains Imidazole) 40 ml See below (0.3 M Imidazole) Imidazole: Emergency Overview
2.3 Other hazards
Harmful by ingestion, Corrosive, Teratogen
2.1 Classification of the substance or mixture
Acute toxicity, Oral (Category r) Skin corrosion (Category 1B) Serious eye damage (Category 1) Reproductive toxicity (Category 1B)
Signal word
Danger
Hazard statements
H302 Harmful if swallowed. H314 Causes severe skin burns and eye damage. H360 May damage fertility or the unborn child.
Precautionary statements
P201 Obtain special instructions before use P280 Wear protective gloves/protective clothing/eye protection/face protection. P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P310 Immediately call a POISON CENTER or doctor/physician.
Health hazards
3 Flammability: 0 3 Fire: 0 Reactivity Hazard: 1
Physical hazards
1
Potential health effects
Inhalation: May be harmful if inhaled. Material is extremely destructive to the tissue of the mucous membranes and upper respiratory tract. Skin: Harmful if absorbed through skin. Causes skin burns. Eyes: Causes eye burns. Ingestion: Harmful if swallowed.