Note: Ingredients listed on restricted chemical lists
General Information
Revision date
2015-02-16
Product name
IgG Foods ELISA Kits
CAS No.
7664-93-9
1.2.2. Uses advised against
Not for use on or in humans
Emergency telephone
1-352-323-3500 (International
Icons in SDS
Company Information
company name
Biomerica
e-mail address of the competent person responsible for the Safety Data Sheet
bmra@biomerica.com
GHS Information
Signal word
Danger
Section 2
SECTION 2: Hazards identification
Appearance Clear for Calibrators and Physical State Liquid Odor None Green for Serum Diluent liquid Red for Conjugate
2.1 Classification of the substance or mixture
Skin corrosion/irritation Category 2 Serious eye damage/eye irritation Category 1
Signal word
Danger
Hazard statements
Causes skin irritation Causes serious eye damage
Prevention
Use personal protective equipment as required Wash face, hands and any exposed skin thoroughly after handling
Response
If exposed or concerned: Get medical advice/attention IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing Immediately call a poison center or doctor/physician IF ON SKIN: Wash with plenty of soap and water If skin irritation occurs: Get medical advice/attention Take off contaminated clothing and wash it before reuse
2.3 Other hazards
Calibrators are formulated with a buffer base, animal or human serum. The kit components that are made with human serum are tested by a United States Food and Drug Administration (USFDA) licensed method and found to be non-reactive for HIV-1, HIV-2, Hepatitis B surface antigen, and HCV. Because no test method can offer absolute assurance that these agents are absent, reagents should be handled at the Biosafety Level 2, as recommended for any potentially infectious human blood product, in the United States Center for Disease Control (USCDC) and National Institute of Health (USNIH) manual "Biosafety in Microbiological Laboratories", 1988. All bovine serum products used are derived from animals of US origin, processed in USDA licensed facilities Wash Buffer, Serum Diluent and Calibrators in kits are formulated with Sodium Azide as a preservative. Concentrated Sodium Azide may react with copper and lead plumbing to form explosive metal azides. It may also react with acids to form explosive hydrazoic acid. If drain disposed, flush with large amounts of water to prevent azide build-up. Avoid contact with Stop Solution containing 1N H2SO4 (Sulfuric Acid),an irritant to the skin and mucous membranes. Substrate Solution A contains Dimethyl Sulfoxide. In case of contact with any of these reagents, wash thoroughly with water