General Information
Revision date
2017-02-10
Product name
VMA by Column Test, REAG 3
CAS No.
7790-28-5
1.2.1 Relevant identified uses
In-Vitro-laboratory reagent or component
1.2.2. Uses advised against
No further relevant information available
Emergency telephone
GBK Gefahrgut Büro GmbH
Icons in SDS
Company Information
company name
Bio-Rad Laboratories Ltd
e-mail address of the competent person responsible for the Safety Data Sheet
techsupport.uk@bio-rad.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H272, H302, H315, H319, H335
Hazard statements
Code
Statements
H272
May intensify fire; oxidiser
Section 2
CLP CLASSIFICATION
Ox. Sol. 2 H272 May intensify fire; oxidiser. Acute Tox. 4 H302 Harmful if swallowed. Skin Irrit. 2 H315 Causes skin irritation. Eye Irrit. 2 H319 Causes serious eye irritation. STOT SE 3 H335 May cause respiratory irritation.
2.2 Label elements
Labelling according to Regulation (EC) No 1272/2008 The product is classified and labelled according to the CLP regulation.
Hazard pictograms
GHS03 GHS07
Signal word
Danger
Hazardous Ingredients
sodium periodate
Hazard statements
H272 May intensify fire; oxidiser. H302 Harmful if swallowed. H315 Causes skin irritation. H319 Causes serious eye irritation. H335 May cause respiratory irritation.
Precautionary statements
P221 Take any precaution to avoid mixing with combustibles. P210 Keep away from heat. - No smoking. P220 Keep/Store away from clothing/combustible materials. P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P405 Store locked up. P501 Dispose of contents/container in accordance with local/regional/national/international regulations.
PBT Substances
Not applicable
vPvB Substances
Not applicable