BP-LFP-1025, BP-LFP-1325, BP-LFP-1375, BP-LFP-1099, BP-LFP-2725

Bicker Elektronik GmbH

Revision date : 2019-05-04

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.
GHS02
Health risk rating 1
Safety risk rating 1
Environmental risk rating 1

Note: Ingredients listed on restricted chemical lists

EC/CAS

96-49-1

Name of the chemical

ethylene carbonate

Concentration

N/A

EC/CAS

616-38-6

Name of the chemical

dimethyl carbonate

Concentration

N/A

General Information

Revision date

2019-05-04

Product name

BP-LFP-1025, BP-LFP-1325, BP-LFP-1375, BP-LFP-1099, BP-LFP-2725

Emergency telephone

Counseling center Giftnotruf München (poison emergency call munich): +49 89 19240

Icons in SDS

GHS02

Company Information

company name

Bicker Elektronik GmbH

e-mail address of the competent person responsible for the Safety Data Sheet

thomas.boehmer@bicker.de

GHS Information

Signal word

Warning!

Section 2

CLP CLASSIFICATION

Not classified as dangerous, if the product is used in accordance with the manufacturer's instructions. S. 1

NFPA Ratings

USA)

EU Classification

WHMIS (Canada)

Hazard pictograms

Not regulated b the WHMIS guidelines. Meets the definition of a „factory made Not classified as article“ and therefore does dangerous not fall under the provisions GHS02 of the Hazardous Products Keep away from open flames

Health hazards

0 and heat sources; keep Act. Fire hazard: 1 fireproof. Reactivity hazard: 0 Protective clothing is not required under normal use. Possible health hazards: Mechanical damage to the batteries or improper use can cause violent reactions that endanger human health and the environment. In particular, high risk potential exists when a battery module is exposed to temperatures in excess of +150°C (e.g., in contact with fire). Is this case, there may be a critical ignition of the battery cells (thermal runaway) – severe fires and bursting oft he battery module are possible in a row. If cell damage occurs, the electrolyte solution in the cell is corrosive and can cause a burn of skin and eye:  Vapors or mists escaping from a damaged cell can cause respiratory irritation.  Ingestion of the contents of an open cell can cause severe chemical burns to the mouth, esophagus and gastrointestinal tract.  Skin contact with the contents of an open cell can cause severe skin irritation or skin burns.  Eye contact with the contents of an open cell can cause serious eye irritation or eye burns.  Direct contact with leaked electrolyte may have a long-term carcinogenic effect. Warning! Never use chargers that are not intended for lithium-iron phosphate chemistry. Do not short circuit. Do not mechanically damage (puncture, deform, disassemble, etc.). Do not heat or burn beyond the allowable temperature. Keep battery modules away from children and animals. Store batteries dry and ideally at room temperature (see also section 7). The lithium battery modules are safe to use when handled properly under the parameters specified in the operating instructions. Improper treatment or conditions that result in improper operation may result in leaking and leakage of battery ingredients and decomposition products, and associated with severe health and environmental hazard reactions. Basically, the contact with leaked battery components can pose a risk to health and the environment. It is therefore necessary to provide adequate body and respiratory protection when in contact with conspicuous batteries (leakage of contents, deformation, discoloration, dentures, etc.) (see section 8: S. 2 Personal protective equipment). Battery packs may e.g. react very violently in combination with fire. In this case, battery components can be emitted with high risk potential. Handling and operational safety: The lithium battery modules should always be handled in accordance with the operating instructions. This applies in particular to compliance with the limits for maximum current load, charge and discharge firing voltages as well as mechanical and thermal loads.. The lithium battery modules may under no circumstances be modified or manipulated as this can lead to considerable safety risks. Charging methods tailored to lithium iron phosphate are to be used. Danger! As with other batteries, lithium batteries are considered to continue to pose a potential hazard in the supposedly discharged state, as they can supply a very high short-circuit current.. Too deep discharge leads to lasting damage. Deeply discharged battery modules may no longer be charged or operated. Deep discharge can occur, for example, during very long storage of a previously discharged to the discharge limit battery module. Excessive charging voltages and overcharging should be avoided under all circumstances. They can lead directly to critical situations, but also have a negative impact on battery life.

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.