Note: Ingredients listed on restricted chemical lists
EC/CAS
68476-86-8
Name of the chemical
Petroleum gases, liquefied, sweetened
Concentration
20-30
EC/CAS
67-56-1
Name of the chemical
Methanol
Concentration
1-10
EC/CAS
108-88-3
Name of the chemical
Toluene
Concentration
0.1-1
General Information
Revision date
2022-04-25
Product name
BG Mass Airflow Sensor Cleaner (Aerosol)
Product Synonyms
P407-xxxx
Manufacturer Name
BG Products, Inc
Emergency telephone
(800) 424-9300
Icons in SDS
Company Information
company name
BG Products, Inc
e-mail address of the competent person responsible for the Safety Data Sheet
msds@bgprod.com
GHS Information
Signal word
Danger
Section 2
Physical hazards
Flammable aerosols Category 1 Gases under pressure Compressed gas
Health hazards
Acute toxicity, dermal Category 4 Acute toxicity, inhalation Category 4 Skin corrosion/irritation Category 2 Serious eye damage/eye irritation Category 2A Reproductive toxicity Category 2 Specific target organ toxicity, single exposure Category 1
Environmental hazards
Not classified. OSHA defined hazards Not classified.
Signal word
Danger
Hazard statements
Extremely flammable aerosol. Contains gas under pressure; may explode if heated. Harmful in contact with skin. Causes skin irritation. Causes serious eye irritation. Suspected of damaging fertility or the unborn child. Causes damage to organs.
Prevention
Obtain special instructions before use. Do not handle until all safety precautions have been read and understood. Keep away from heat/sparks/open flames/hot surfaces. - No smoking. Do not spray on an open flame or other ignition source. Pressurized container: Do not pierce or burn, even after use. Do not breathe mist/vapors. Wash thoroughly after handling. Do not eat, drink or smoke when using this product. Wear protective gloves/protective clothing/eye protection/face protection.
Response
If on skin Wash with plenty of water. If in eyes Rinse cautiously with water for several minutes Remove contact lenses, if present and easy to do. Continue rinsing. If exposed or concerned: Get medical advice/attention. If skin irritation occurs: Get medical advice/attention. If eye irritation persists: Get medical advice/attention. Take off contaminated clothing and wash it before reuse.
Storage
Store locked up. Protect from sunlight. Store in a well-ventilated place. Do not expose to temperatures exceeding 50°C/122°F.
Disposal
Dispose of contents/container in accordance with local/regional/national/international regulations. Hazard(s) not otherwise Static accumulating flammable liquid can become electrostatically charged even in bonded and
Classified (HNOC)
grounded equipment. Sparks may ignite liquid and vapor. May cause flash fire or explosion.
Additional information
70% of the mixture consists of component(s) of unknown acute hazards to the aquatic environment. 70% of the mixture consists of component(s) of unknown long-term hazards to the aquatic environment.