Note: Ingredients listed on restricted chemical lists
EC/CAS
919-857-5/64742-48-9
Name of the chemical
Naphtha (petroleum), hydrotreated heavy
Concentration
N/A
EC/CAS
219-535-8/2457-01-4
Name of the chemical
Barium bis(2-ethylhexanoate)
Concentration
N/A
EC/CAS
205-250-6/136-52-7
Name of the chemical
Cobalt bis(2-ethylhexanoate)
Concentration
N/A
General Information
Revision date
2017-05-30
Product name
SOLO GOYA Cobalt Sikkativ
1.2.1 Relevant identified uses
Accelerates surface drying of artist oil color. For artists and hobby user
supplier name
F&E
Emergency telephone
Fon
Icons in SDS
Company Information
company name
Bettina Treiber
e-mail address of the competent person responsible for the Safety Data Sheet
info@c-kreul.de, b.treiber@c-kreul.de
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H226, H304, H317, H336, H361d
Hazard statements
Code
Statements
H226
Flammable liquid and vapour
Section 2
CLP CLASSIFICATION
Flam. Liq. 3 H226; Asp. Tox. 1 H304; Skin Sen. 1 H317; STOT SE 3 H336; Repr. 2 H361d Labelling according to Regulation (EC) 1272/2008 Hazard pictogram and signal word of the product Danger
Hazardous Ingredients
Hydrocarbons, C9-C11, n-Alkanes, Isoalkanes, Cyclics, Aromates (< 2%) EG 919-857-5; 2- ethylhexanoic acid, zirconium salt CAS 22464-99-9; cobalt bis(2-ethylhexanoate) CAS 136-52- 7.
Hazard statements
H226 Flammable liquid and vapour. H304 May be fatal if swallowed and enters airways. H317 May cause an allergic skin reaction. H336 May cause drowsiness or dizziness. H361d Suspected of damaging the unborn child European hazard statements EUH -
Precautionary statements
P101 If medical advice is needed, have product container or label at hand. P102 Keep out of reach of children. P243 Take precautionary measures against static discharge. P271 Use only outdoors or in a well-ventilated area. P301+P310+P331 IF SWALLOWED: Immediately call a POISON CENTER or doctor/ physician. Do NOT induce vomiting. P302+P352 IF ON SKIN: Wash with plenty of soap and water. P370+P378 In case of fire: Use sand, carbon dioxide or powdered extinguishing agent for extinction. P405 Store locked up. P501 Dispose of contents/container to hazardous or special waste collection point.
2.3 Other hazards
Vapours may form explosive mixtures with air. This material is combustible and can be ignited by heat, sparks, flames, or other sources of ignition (e.g. static electricity, pilot lights, or mechanical/ electrical equipment). Take precautionary measures against static discharges.
Results of PBT and vPvB assessment
Not applicable