Note: Ingredients listed on restricted chemical lists
EC/CAS
238-877-9/14807-96-6
Name of the chemical
Talc
Concentration
>1.00
EC/CAS
223-289-7/3811-04-9
Name of the chemical
Potassium chlorate
Concentration
>1.00
General Information
Revision date
2021-09-23
Product name
COOPEX MAXI SMOKE GENERATOR
supplier name
Bayer Environmental Science
Icons in SDS
Company Information
company name
bayer cropscience
e-mail address of the competent person responsible for the Safety Data Sheet
ukcropsupport@bayer.com
GHS Information
Signal word
Warning
Hazard Codes
Hazard statements (CLP)
H302, H317, H319, H335, H400, H410
Hazard statements
Code
Statements
H302
Harmful if swallowed
Section 2
2.1 Classification of the substance or mixture
Classification in accordance with Regulation (EC) No 1272/2008 on classification, labelling and packaging of substances and mixtures, as amended. Acute toxicity: Category 4 H302 Harmful if swallowed. Skin sensitisation: Category 1 H317 May cause an allergic skin reaction. Eye irritation: Category 2 H319 Causes serious eye irritation. Specific target organ toxicity - single exposure: Category 3 H335 May cause respiratory irritation. Acute aquatic toxicity: Category 1 H400 Very toxic to aquatic life. Chronic aquatic toxicity: Category 1 H410 Very toxic to aquatic life with long lasting effects.
2.2 Label elements
Labelling in accordance with Regulation (EC) No 1272/2008 on classification, labelling and packaging of substances and mixtures, as amended. Hazard label for supply/use required.
Hazardous Ingredients
Permethrin • Potassium chlorate
Hazard statements
H302 Harmful if swallowed. H317 May cause an allergic skin reaction. H319 Causes serious eye irritation. H335 May cause respiratory irritation. H410 Very toxic to aquatic life with long lasting effects. EUH401 To avoid risks to human health and the environment, comply with the instructions for use.
Precautionary statements
P280 Wear protective gloves/protective clothing/eye protection/face protection. P308 + P311 IF exposed or concerned: Call a POISON CENTER/ doctor/ physician. P501 Dispose of contents/container to a licensed hazardous-waste disposal contractor or collection site except for empty clean containers which can be disposed of as non- hazardous waste.
2.3 Other hazards
Cutaneous sensations may occur, such as burning or stinging on the face and mucosae. However, these sensations cause no lesions and are of a transitory nature (max. 24 hours). Ignites readily. Product burns without a flame to give a dense white harmful smoke. May form explosible dust-air mixture if dispersed. Permethrin: This substance is not considered to be persistent, bioaccumulative and toxic (PBT). This substance is not considered to be very persistent and very bioaccumulative (vPvB).