General Information
Revision date
2000-02-24
Product name
Lustran ABS 248-1050 Natural
Icons in SDS
Company Information
company name
BAYER CORPORATION
Section 2
SECTION 2: Hazards identification
OSHA (Continued) a a ee ee * intense heat and dense smoke during burning. * dededededekdedededbde ke ededededede dcdcdc dead detekde dese teak kee ke de dete te de te ea KKK KT RR RIKRKEKK KER
Potential health effects
ROUTE(S) OF ENTRY...........+eee-2-3 Inhalation; Eye Contact; Skin Contact HUMAN EFFECTS AND SYMPTOMS OF OVEREXPOSURE: ACUTE EFFECTS OF EXPOSURE.....: Material is a non-reactive solid. Mechanical irritation (i.e. abrasion) to the eyes may occur due to exposure to fines. Eyes may become red and scratchy and may tear. Several ABS resins have been tested for potential to produce allergic skin reaction in controlled skin contact studies with human volunteers. A potential for cumulative irritation was demonstrated but primary irritation and allergic skin reactions were not observed. Gases and fumes evolved from this material may irritate the eyes, skin or respiratory tract. At processing temperatures small amounts of styrene, ethylbenzene and acrylonitrile may be emitted. Prolonged and repeated exposure of high concentrations of these vapors and fumes (due to inadequate ventilation, etc.) could cause nausea, drowsiness and headache.
Potential chronic health
OF EXPOSURE...: In October 1988, the National Institute for Occupational Safety and Health (NIOSH) concluded that "...there seems to be little basis from experimental animal investigations or epidemiologic studies to conclude at this time that styrene is carcinogenic." Additionally, both EPA's Scientific Advisory Board and the Expert Committee of the commission of the European Communities evaluating the same information found insufficient evidence to classify styrene as a carcinogen. 7 CARCINOGENICITY NTP. cece ecccceseceseseseess Not listed as a carcinogen TARC. cc csccecccccsceceesesvess Styrene (CAS# 100-42-5); Classified as IARC Possible Human Carcinogen (Group 2B) "The chemical or group of chemicals is possibly carcinogenic for humans."
Medical Conditions Generally Aggravated by Exposure
Preexisting eye, skin or respiratory tract sensitivities. EXPOSURE LIMITS............+.-.: For product fines the OSHA-PEL for nuisance dust of 15 mg/m3 total dust, 5 mg/m3 respirable dust is recommended. In addition, the ACGIH-TLV for Particulates Not Otherwise Classified (PNOC) of 10 mg/m3 is recommended. Observe a more stringent limit for product fines if applicable. See Section 2. For product gases and fumes refer to the exposure limits listed in Section 2. Product Code: P1519581 MSDS Page 2 3 Approval Date: 02/24/2000 Continued on next page me a i ee ee ee ee ee ee en en ee a ee ee ee FIRST AID FOR EYES......: Flush eyes with plenty of lukewarm water. See physician if irritation persists. FIRST AID FOR SKIN......: Wash affected areas with soap and water. See physician if thermal burn occurs. FIRST AID FOR INHALATION: Remove to fresh air. If breathing is difficult, get medical attention. FIRST AID FOR INGESTION.: Contact a physician. —— _ — ee mn in i ne i i ee FLASH POINT... ..ccccecceceeseeees 730-752F (388-400C) FLAMMABLE LIMITS: UPPER EXPLOSIVE LIMIT (UEL) (%): Not applicable LOWER EXPLOSIVE LIMIT (LEL) (4): Not applicable AUTO-IGNITION TEMPERATURE.......: 923-950F (495-510C) EXTINGUISHING MEDIA.........++++2 Water; Dry Chemical; Carbon Dioxide; Foam