Note: Ingredients listed on restricted chemical lists
EC/CAS
403-730-1/2687-96-9
Name of the chemical
N-(n-dodecyl)pyrrolidinone
Concentration
<1%
EC/CAS
203-856-5/111-30-8
Name of the chemical
Glutaral
Concentration
<0,1% 605-022-
General Information
Revision date
2020-05-18
Product name
Helimatic Cleaner neutral
1.2.1 Relevant identified uses
Instrument cleaner
supplier name
B. Braun Melsungen AG
Manufacturer Name
B. Braun Medical AG
Emergency telephone
INTERNATIONAL: +49 - (0) 6132 - 84463, GBK GmbH (24h - 7d/w - 365d/a
Icons in SDS
Company Information
company name
B. Braun Melsungen AG
e-mail address of the competent person responsible for the Safety Data Sheet
info.bbmch@bbraun.com, logistics.service@bbraun.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H318, H412
Hazard statements
Code
Statements
H318
Causes serious eye damage
Section 2
2.1 Classification of the substance or mixture
Regulation (EC) No. 1272/2008
Hazard categories
Serious eye damage/eye irritation: Eye Dam. 1 Hazardous to the aquatic environment: Aquatic Chronic 3
Hazard statements
Causes serious eye damage. Harmful to aquatic life with long lasting effects. H318 Causes serious eye damage. H412 Harmful to aquatic life with long lasting effects. H318-H412
2.2 Label elements
Regulation (EC) No. 1272/2008
Hazardous Ingredients
Glycolic acid ethoxylate octyl ether
Signal word
Danger Danger
Precautionary statements
P280 Wear protective gloves and eye/face protection. P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P310 Immediately call a POISON CENTER/doctor. P273 Avoid release to the environment. P501 Dispose of contents/container to an approved waste disposal plant. . P280-P305+P351+P338-P310
Special rules for supplemental label elements for certain mixtures
EUH208
Contains
1-dodecyl-2-pyrrolidone, Glutaraldehyde. May produce an allergic reaction Labelling of packages where the contents do not exceed 125 ml
2.3 Other hazards
According to Regulation (EC) No 1907/2006 (REACH) none of the substances, contained in this product are a
vPvB Substances
High risk of slipping due to leakage/spillage of product.