PERMAHYD HI-TEC MIXING COLOR ULTRA DEEP BLACK

Axalta Coating Systems, LLC

Revision date : 2020-02-28

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.
GHS05 GHS07 GHS08
Health risk rating 5
Safety risk rating 1
Environmental risk rating 1

Note: Ingredients listed on restricted chemical lists

EC/CAS

71-41-0

Name of the chemical

1-pentanol

Concentration

N/A

EC/CAS

117527-94-3

Name of the chemical

A mixture of: tert-alkyl(C12-C14)ammonium bis[1-[(2-hydroxy-5-nitrophenyl)azo]-2-naphthalenolato(2-)]-chromate(1-); tert-alkyl(C12-C14)ammonium bis[1-[(2-hydroxy-4-nitrophenyl)azo]-2-naphthalenolato(2-)]-chromate(1-); tert-alkyl(C12-C14)ammonium bis[1-[[5

Concentration

N/A

Listed in

General Information

Revision date

2020-02-28

Product name

PERMAHYD HI-TEC MIXING COLOR ULTRA DEEP BLACK

supplier name

Axalta Coating Systems, LLC

Emergency telephone

800-424-9300

Icons in SDS

GHS05 GHS07 GHS08

Company Information

company name

Axalta Coating Systems, LLC

GHS Information

Signal word

Danger

Hazard Codes

Hazard statements (CLP)

H317, H318, H351, H360

Hazard statements

Code

Statements

H317

May cause an allergic skin reaction

Section 2

SECTION 2: Hazards identification

OSHA OSHA/HCS status : This material is considered hazardous by the OSHA Hazard Communication Standard (29 CFR 1910.1200).

2.1 Classification of the substance or mixture

SERIOUS EYE DAMAGE - Category 1 SKIN SENSITIZATION - Category 1 CARCINOGENICITY - Category 2 TOXIC TO REPRODUCTION (Fertility) - Category 1B TOXIC TO REPRODUCTION (Unborn child) - Category 1B

Ingredient(s) with unknown acute toxicity

1.8% 1.1% toxicity: 8.8%

Signal word

Danger

Hazard statements

H318 - Causes serious eye damage. H317 - May cause an allergic skin reaction. H360 - May damage fertility or the unborn child. H351 - Suspected of causing cancer.

Prevention

P201 - Obtain special instructions before use. P202 - Do not handle until all safety precautions have been read and understood. P280 - Wear protective gloves. Wear eye or face protection. Wear protective clothing. P261 - Avoid breathing vapor. P272 (OSHA) - Contaminated work clothing must not be allowed out of the workplace.

Response

P308 + P313 - IF exposed or concerned: Get medical attention. P302 + P352 + P363 - IF ON SKIN: Wash with plenty of soap and water. Wash contaminated clothing before reuse. P333 + P313 - If skin irritation or rash occurs: Get medical attention. P305 + P351 + P338 + P310 - IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER or physician.

Storage

P405 - Store locked up.

Disposal

P501 - Dispose of contents and container in accordance with all local, regional, national and international regulations.

2.3 Other hazards

None known.

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.