Note: Ingredients listed on restricted chemical lists
EC/CAS
77-58-7
Name of the chemical
Dibutylzinndilaurat; Dibutyl[bis(dodecanoyloxy)]stannan (2017/776)
Concentration
N/A
General Information
Revision date
2021-10-12
Product name
Fleet-Thane & Ful-Thane HS Accelerator
1.2.2. Uses advised against
Not for sale to or use by consumers
supplier name
Axalta Coating Systems, LLC
Emergency telephone
800-424-9300
Icons in SDS
Company Information
company name
Axalta Coating Systems, LLC
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H226, H302, H311+H331, H317, H360
Hazard statements
Code
Statements
H226
Flammable liquid and vapour
Section 2
SECTION 2: Hazards identification
29 CFR 1910.1200) OSHA/HCS status : This material is considered hazardous by the OSHA Hazard Communication Standard (29 CFR 1910.1200).
2.1 Classification of the substance or mixture
FLAMMABLE LIQUIDS - Category 3 ACUTE TOXICITY (oral) - Category 4 ACUTE TOXICITY (dermal) - Category 3 ACUTE TOXICITY (inhalation) - Category 3 SKIN SENSITIZATION - Category 1 TOXIC TO REPRODUCTION - Category 1B
Signal word
Danger
Hazard statements
H226 - Flammable liquid and vapor. H302 - Harmful if swallowed. H311 + H331 - Toxic in contact with skin or if inhaled. H317 - May cause an allergic skin reaction. H360 - May damage fertility or the unborn child.
Prevention
P201 - Obtain special instructions before use. P280 - Wear protective gloves, protective clothing and eye or face protection. P210 - Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P241 - Use explosion-proof electrical, ventilating or lighting equipment. P242 - Use non-sparking tools. P243 - Take action to prevent static discharges. P261 - Avoid breathing vapor. P270 - Do not eat, drink or smoke when using this product. P264 - Wash thoroughly after handling.
Response
P308 + P313 - IF exposed or concerned: Get medical advice or attention. P304 + P340, P311 - IF INHALED: Remove person to fresh air and keep comfortable for breathing. Call a POISON CENTER or doctor. P361 + P364 - Take off immediately all contaminated clothing and wash it before reuse. P302 + P312, P352 - IF ON SKIN: Call a POISON CENTER or doctor if you feel unwell. Wash with plenty of water. P333 + P313 - If skin irritation or rash occurs: Get medical advice or attention.
Storage
P403 + P235 - Store in a well-ventilated place. Keep cool.
Disposal
P501 - Dispose of contents and container in accordance with all local, regional, national and international regulations.
2.3 Other hazards
None known.