Note: Ingredients listed on restricted chemical lists
EC/CAS
7646-79-9
Name of the chemical
Cobalt dichloride
Concentration
<0.3%
General Information
Version
1.4
Revision date
2025-08-26
Product name
Silica Gel Desicant, Indicating (4-10 Mesh) BAKER ANALYZED Reagent
Product Synonyms
none
1.2.1 Relevant identified uses
For Laboratory, Research or Manufacturing Use
supplier name
Avantor Performance Materials, LLC
Emergency telephone
+1-855-282-6867, +1-610-573-2610, +1-800-424-9300
Icons in SDS
Company Information
company name
Avantor Performance Materials, LLC
e-mail address of the competent person responsible for the Safety Data Sheet
SDS@avantorsciences.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H350, H360
Hazard statements
Code
Statements
H350
May cause cancer
Section 2
SECTION 2: Hazards identification
Health hazards
Carcinogenicity, category 1B Reproductive toxicity, category 1B
Signal word
Danger
Hazard statements
H350 - May cause cancer. H360 - May damage fertility or the unborn child.
Prevention
P201 - Obtain special instructions before use. P202 - Do not handle until all safety precautions have been read and understood. P280 - Wear protective gloves/protective clothing/eye protection/face protection.
Response
P308+P313 - IF exposed or concerned: Get medical advice/attention.
Storage
P405 - Store locked up.
Disposal
P501 - Dispose of contents/container to an appropriate treatment or disposal facility in accordance with applicable laws and regulations. Hazard(s) not otherwise classified (HNOC) none