BioPlex 2200 HIV Ag-Ab Calibrator Set

Australia: Bio-Rad Laboratories Pty. Ltd.

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.
GHS07
Health risk rating 4
Safety risk rating 1
Environmental risk rating 3

Note: Ingredients listed on restricted chemical lists

EC/CAS

2682-20-4

Name of the chemical

2-Methyl-2H-isothiazol-3-one

Concentration

N/A

EC/CAS

26172-55-4

Name of the chemical

5-chloro-2-methyl-4-thiazoline-3-ketone

Concentration

N/A

EC/CAS

55965-84-9

Name of the chemical

Mixture of 5-chloro-2-methyl-2H- isothiazol-3-one (EINECS 247-500-7) and 2-methyl-2H-isothiazol-3-one (EINECS 220-239-6)

Concentration

N/A

EC/CAS

26628-22-8

Name of the chemical

Sodium Azide

Concentration

N/A

EC/CAS

220-239-6

Name of the chemical

Mixture of 5-Chloro-2-methyl-isothiazol-3(2H)-one and 2-methylisothiazol-3(2H)-one

Concentration

N/A

EC/CAS

247-500-7

Name of the chemical

Mixture of 5-Chloro-2-methyl-isothiazol-3(2H)-one and 2-methylisothiazol-3(2H)-one

Concentration

N/A

General Information

Product name

BioPlex 2200 HIV Ag-Ab Calibrator Set

Manufacturer Name

Bio-Rad Laboratories, Inc

Emergency telephone

(24h/365d) 1 800 039 008

Icons in SDS

Company Information

company name

Australia: Bio-Rad Laboratories Pty. Ltd.

e-mail address of the competent person responsible for the Safety Data Sheet

ro-sds@bio-rad.com, fds-msds.fr@bio-rad.com, sales.australia@bio-rad.com, sales.nz@bio-rad.com

GHS Information

Signal word

Warning

Hazard Codes

Hazard statements (CLP)

H317, H412

Hazard statements

Code

Statements

H317

May cause an allergic skin reaction

H412

Harmful to aquatic life with long lasting effects

Section 2

SECTION 2: Hazards identification

HAZARDOUS COMPONENTS This test kit should be handled only by qualified personnel trained in laboratory procedures and familiar with their potential hazards. Specific warnings are given in the instructions for use. The absence of a specific warning should not be interpreted as an indication of safety. The following information is furnished for those product hazardous constituents that require regulatory control or disclosure at the concentration found in the product. Refer to Section 16 for the full text of any solely abbreviated or coded

Hazard statements

provided below and for the key / legend to abbreviations and acronyms Component

Contains

CAL 1] - Antigen Calibrator containing purified HIV-1 p24 antigen (from viral lysate inactivated with a chaotropic agent) in a HIV Antigen Tris buffer [CAS# 77-86-1] with protein stabilizer (bovine, CAS# 9048-46-8) . Calibrator - < 1% Sodium chloride [NaCl, CAS# 7647-14-5, EC No 231-598-3]. Not subject to GHS, US HCS, EC CLP and BioPlex 2200 analogous global GHS-based regulatory requirements in this product mixture and concentration HIV Ag-Ab - Preserved with  0.3% ProClin 300 ( 0.009% active ingredient), EC Index No 613-167-00-5 with CAS# 55965-84-9 GHS \ US HCS \ EC CLP Classification: WARNING; GHS07; H317, H412; P273, P280; P302 + P352, P333 + P313; Three (3) vials P501. with 0.8 mL - Preserved with  0.1% sodium benzoate [C7H5O2Na], CAS# 532-32-1, EC No 208-534-8. Not subject to GHS, US HCS, EC CLP and analogous global GHS-based regulatory requirements in this product mixture and concentration - Preserved with < 0.1% sodium azide [NaN3], CAS# 26628-22-8 and EC No 247-852-1. Not subject to GHS, US HCS, WARNING EC CLP and analogous global GHS-based regulatory requirements in this product mixture and concentration [CAL 2] - Antibody Calibrator containing human antibodies to HIV-1 Group M and HIV-2, and purified rabbit antibody to HIV-1 HIV-1/HIV-2 Group O in Tris buffer [CAS# 77-86-1], protein stabilizer (bovine, CAS# 9048-46-8). Human plasma used in Antibody preparing this calibrator has been inactivated (heat-treated Human serum/plasma containing HIV-1 and HIV-2 immunoglobulin, non-reactive for HBsAg and antibody to HCV. Calibrator - < 1% Sodium chloride [NaCl], CAS# 7647-14-5, EC No 231-598-3. Not subject to GHS, US HCS, EC CLP and BioPlex 2200 analogous global GHS-based regulatory requirements in this product mixture and concentration HIV Ag-Ab Three (3) vials - Preserved with  0.3% ProClin 300 ( 0.009% active ingredient), EC Index No 613-167-00-5 with CAS# 55965-84-9 GHS \ US HCS \ EC CLP Classification: WARNING; GHS07; H317, H412; P273, P280; P302 + P352, P333 + P313; with 0.8 mL P501. - Preserved with  0.1% sodium benzoate [C7H5O2Na], CAS# 532-32-1, EC No 208-534-8. Not subject to GHS, US HCS, EC CLP and analogous global GHS-based regulatory requirements in this product mixture and concentration - Preserved with < 0.1% sodium azide [NaN3], CAS# 26628-22-8 and EC No 247-852-1. Not subject to GHS, US HCS, WARNING EC CLP and analogous global GHS-based regulatory requirements in this product mixture and concentration Markings according to the United Nations (UN) Globally Harmonized System (GHS), United States Hazard Communication Standard (US HCS) and European Commission (EC) 2008/1272/EC (EC CLP) guidelines and analogous GHS-based global regulations: This product has been conservatively classified and labeled in accordance with applicable United Nations (UN) GHS, United States Hazard Communication Standard (US HCS), related European Commission (EC) 2008/1272/EC (EC CLP) guidelines and applicable analogous GHS-based global regulations. The following regulated hazardous chemical concentrations are found in product component(s): SDSen663-3400 Revision G (February 2020) 2 of 15 (OUS) [Catalog 663-3400]  0.3% ProClin 300 [ 0.009% active ingredients – reaction mass of: 5-chloro-2-methyl-4-isothiazolin-3-one (C4H4ClNOS; CAS# 26172-55-4, EC No 247-500-7) and 2-methyl-2H -isothiazol-3-one (C4H5NOS; CAS# 2682-20-4, EC No 220-239-6) (3:1)], EC Index No 613-167-00-5 with CAS# 55965-84-9. Comprehensive GHS Based Classification: Skin Sensitizer Category 1 Label(s): GHS07

Signal word

WARNING Label Hazard Statement: H317 May cause an allergic skin reaction. H412 Harmful to aquatic life with long lasting effects.

Precautionary statements

statements for product intended use and as codified on the product label) P273 Avoid release to the environment. P280 Wear protective gloves / protective clothing / eye protection / face protection. P302 + P352 IF ON SKIN: Wash with plenty of soap and water. P333 + P313 If skin irritation or rash occurs: Get medical advice/ attention. P501 Dispose of contents and container in accordance to local, regional, national and international regulations.

Supplemental label elements

additional precautions to consider relative to specific customer use) P261 Avoid breathing mist / vapours / spray. P272 Contaminated work clothing should not be allowed out of the workplace. [Source: Raw Material vendor SDS, CCOHS databases and regulatory research]=

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.