Isoset UX 160 WD3-A322 100 ADHESIVE

Ashland

Revision date : 2014-01-29

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.
Health risk rating 1
Safety risk rating 1
Environmental risk rating 1

Note: Ingredients listed on restricted chemical lists

EC/CAS

9016-87-9

Name of the chemical

4,4'-Methylendiphenyldiisocyanat tech. (Polymeres) MDI, pMDI (in Form atembarer Aerosole, A-Fraktion)

Concentration

N/A

EC/CAS

101-68-8

Name of the chemical

4,4’-Methylenediphenyl diisocyanate

Concentration

N/A

EC/CAS

26447-40-5

Name of the chemical

Methylenediphenyl diisocyanate (see also specific isomers)

Concentration

N/A

EC/CAS

14464-46-1

Name of the chemical

Cristobalit (s. u. TRGS 906)

Concentration

N/A

General Information

Revision date

2014-01-29

Product name

Isoset UX 160 WD3-A322 100 ADHESIVE

1.2.2. Uses advised against

No data

Emergency telephone

1-800-ASHLAND (1-800-274-5263

Icons in SDS

Company Information

company name

Ashland

GHS Information

Signal word

WARNING!

Section 2

SECTION 2: Hazards identification

Emergency Overview Appearance: liquid WARNING! MAY CAUSE ALLERGIC SKIN OR RESPIRATORY REACTION. MAY CAUSE EYE, SKIN AND RESPIRATORY TRACT IRRITATION. PROLONGED OR REPEATED CONTACT MAY DRY SKIN, CAUSE IRRITATION AND BURNS.

Principle Routes of Exposure

Inhalation, Skin absorption, Skin contact, Eye Contact, Ingestion, This product is an inert plastic when fully cured, and as such, is nonhazardous. Exposure to unreacted chemicals can occur when handling the individual components in pails or when using cartridges from the time of dispensing until the mixed material has cured. The mixed material is actually curing as it is dispensed in an increasingly viscous form, making it unlikely to present an inhalation hazard. The semi-viscous mixture does not flow like a liquid when dispensed, thus minimizing the possibility of accidental skin contact. Eye contact Can cause eye irritation. Symptoms include stinging, tearing, redness, and swelling of eyes. Skin contact Can cause skin irritation. Symptoms may include redness and burning of skin, and other skin damage. Skin contact with adhesive that is not fully cured may cause an allergic skin reaction or other skin irritation. Ingestion Swallowing small amounts of this material during normal handling is not likely to cause harmful effects. Swallowing large amounts may be harmful. Inhalation Breathing of vapor or mist is possible. This product contains 4,4'-diphenylmethane diisocyanate (MDI). Breathing MDI may cause an allergic respiratory reactionwith difficult breathing and chest pain. The onset of respiratory symptoms may be delayed for several hours after exposure. Previously sensitized individuals should avoid exposure to all diisocyanates because exposure to even very small amounts can cause asthma-like attacks in these individuals. Symptoms are not expected at air concentrations below the recommended exposure limits, if applicable (see Section 8.).

Medical Conditions Generally Aggravated by Exposure

Preexisting disorders of the following organs (or organ systems) may be aggravated by exposure to this material:, Skin, Upper respiratory tract, lung (for example, asthma-like conditions) Symptoms Signs and symptoms of exposure to this material through breathing, swallowing, and/or passage of the material through the skin may include:, stomach or intestinal upset (nausea, vomiting, diarrhea), irritation (nose, throat, airways), runny nose, Cough, Headache, chest pain, lung edema (fluid buildup in the lung tissue), Exposure to this product (or a component) may cause an allergic reaction (narrowing of the air passages of the lungs resulting in difficult breathing, tightness in the chest, coughing and wheezing) in some sensitive individuals. Other symptoms of an allergic reaction may include itchy and watery eyes, runny and stuffy nose, sweating, flushing, hives, rapid heart rate, and lowered blood pressure., Difficulty in breathing Target Organs Overexposure to this material (or its components) has been suggested as a cause of the following effects in laboratory animals , nasal damage, lung damage, Overexposure to this material (or its components) has been suggested as a cause of the following effects in humans , effects on lung function Carcinogenicity In a two-year inhalation study in rats, exposure to polymeric methylene bisphenylisocyanate (MDI) aerosol caused a significant increase in benign (noncarcinogenic) lung tumors, along with a single carcinogenic lung tumor, at the highest dose only (6 mg/m3). The tumors occurred along with irritation of the respiratory tract and the accumulation of a yellow material in the lungs. There was irritation only at 1.0 mg/m3 and no effect at 0.2 mg/m3. MDI is not listed as carcinogenic by the International Agency for Research on Cancer (IARC), the National Toxicology Program (NTP) or the Occupational Safety and Health Administration (OSHA). The International Agency for Research on Cancer (IARC) and the National Toxicology Program (NTP) have determined that there is sufficient evidence in humans for the carcinogenicity of inhaled crystalline silica in the form of quartz or cristobalite. In addition, IARC has determined that there is sufficient evidence for the carcinogenicity of quartz and cristobalite in experimental animals. Among individuals with silicosis, lung cancer occurs more frequently in those who smoke. Reproductive hazard This material (or a component) has been shown to cause harm to the fetus in laboratory animal studies. Harm to the fetus occurs only at exposure levels that harm the pregnant animal. The relevance of these findings to humans is uncertain.

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.