General Information
Revision date
2018-08-03
Product name
LUPEROX AIR XL
Chemical name
Organic peroxide
1.2.1 Relevant identified uses
Cross-linking agent for polymers and elastomers
Emergency telephone
(800) 424-9300
Icons in SDS
Company Information
company name
Arkema Inc
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H242, H317, H412
Hazard statements
Code
Statements
H242
Heating may cause a fire
Section 2
SECTION 2: Hazards identification
Emergency Overview Color: off-white Physical state: solid Form: powder Odor: pungent, unpleasant
2.1 Classification of the substance or mixture
Organic peroxides, Type D, H242 Skin sensitisation, Category 1, H317 Chronic aquatic toxicity, Category 3, H412 *For the full text of the H-Statements mentioned in this Section, see Section 16.
Signal word
Danger
Hazard statements
H242 : Heating may cause a fire. H317 : May cause an allergic skin reaction. H412 : Harmful to aquatic life with long lasting effects.
Supplemental label elements
Organic peroxide. Hazardous decomposition may occur. May form combustible dust concentrations in air.
Prevention
P210 : Keep away from heat/sparks/open flames/hot surfaces. No smoking. P220 : Keep/Store away from clothing/ combustible materials. P234 : Keep only in original container. P261 : Avoid breathing dust/ fume/ gas/ mist/ vapours/ spray. P272 : Contaminated work clothing should not be allowed out of the workplace. P273 : Avoid release to the environment. P280 : Wear protective gloves/ eye protection/ face protection.
Response
P302 + P352 IF ON SKIN Wash with plenty of soap and water P333 + P313 If skin irritation or rash occurs Get medical advice/ attention P363 : Wash contaminated clothing before reuse.
Storage
P410 : Protect from sunlight. P411 + P235 : Maximum storage temperature is specified on label and in section 7 of SDS. Keep cool. P420 : Store away from other materials.
Disposal
P501 : Dispose of contents/ container to an approved waste disposal plant.
Potential health effects
Mechanical irritation effects from dust exposure are possible at ambient temperature. .