Acetylene, Dissolved

Arc3 Gases

Revision date : 2025-06-17

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.
GHS04 GHS02
Health risk rating 1
Safety risk rating 4
Environmental risk rating 1

Note: Ingredients listed on restricted chemical lists

EC/CAS

74-86-2

Name of the chemical

acetylene

Concentration

100%

General Information

Revision date

2025-06-17

Product name

Acetylene, Dissolved

CAS No.

74-86-2

1.2.2. Uses advised against

Not Known Usage Restrictions

Emergency telephone

1-800-535-5053

Icons in SDS

GHS02 GHS04

Company Information

company name

Arc3 Gases

GHS Information

Signal word

Danger

Hazard Codes

Hazard statements (CLP)

H220, H280

Hazard statements

Code

Statements

H220

Extremely flammable gas

Section 2

SECTION 2: Hazards identification

Hazard Classification Flammable (Category 1), H220 Gases Under Pressure, H280 Simple Asphyxiant, OSHA-H01 Hazard Statements H220: Extremely flammable gas H280: Contains gas under pressure; may explode if heated CGA-HG04: MAY FORM EXPLOSIVE MIXTURES WITH AIR OSHA-H01: MAY DISPLACE OXYGEN AND CAUSE RAPID SUFFOCATION

Precautionary statements

P202: Do not handle until all safety precautions have been read and understood. P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P271+P403: Use and store only outdoors or in a well-ventilated place. P377 Leaking gas fire Do not extinguish, unless leak can be stopped safely P381: In case of leakage, eliminate all ignition sources. CGA-PG02: Protect from sunlight when ambient temperature exceeds 52C (125F). CGA-PG05: Use a back flow preventive device in the piping. CGA-PG06: Close valve after each use and when empty. CGA-PG10+CGA-PG20: Use only with equipment of compatible materials of construction and rated for cylinder pressure. CGA-PG11: Never put cylinders into unventilated areas of passenger vehicles. CGA-PG12: Do not open valve until connected to equipment prepared for use. CGA-PG13: Fusible plugs in top, bottom, or valve melt at 98C to 107C (208F to 224F). Do not discharge at pressures above 15 psi (103 kPa). CGA-PG27: Read and follow the Safety Data Sheet (SDS) before use.

2.1 Classification of the substance or mixture

Flammable (Category 1), H220 Gases Under Pressure, H280 Simple Asphyxiant, OSHA-H01 Hazard Statements: H220: Extremely flammable gas H280: Contains gas under pressure; may explode if heated CGA-HG04: MAY FORM EXPLOSIVE MIXTURES WITH AIR. OSHA-H01: MAY DISPLACE OXYGEN AND CAUSE RAPID SUFFOCATION.

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.