General Information
Revision date
2015-05-22
Product name
Gd
CAS No.
7440-54-2
1.2.2. Uses advised against
Not for food or drug use
Emergency telephone
+01-813-248-0585, 800-255-3924
Icons in SDS
Company Information
company name
APL Engineered Materials, Inc
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H261
Hazard statements
Code
Statements
H261
In contact with water releases flammable gas
Section 2
SECTION 2: Hazards identification
2.1: Classifications Substances which, in contact with water, emit flammable gases - Category 3 2.2: GHS Label Elements
Hazard statements
H261: In contact with water releases flammable gases.
Precautionary statements
P231 + P232: Handle under inert gas. Protect from moisture. P280: Wear protective gloves, clothing, and eyewear. face protection P370 + P378 In case of fire Use dry chemical or class D metal agent for extinction P402 + P404: Store in a dry place. Store in a closed container. P501: Dispose of contents/container to licensed disposal facility. 2.3: Hazards Not Otherwise Classified or Not Covered by GHS None. 2.4: Amount(s) of substances with unknown toxicity None
2.1 Classification of the substance or mixture
Substances which, in contact with water, emit flammable gases - Category 3