Note: Ingredients listed on restricted chemical lists
EC/CAS
7440-02-0
Name of the chemical
Nickel
Concentration
40-60 20-30
EC/CAS
64742-52-5
Name of the chemical
Distillates (petroleum), hydrotreated heavy naphthenic
Concentration
5-15 1-5
EC/CAS
7727-37-9
Name of the chemical
Nitrogen N2
Concentration
1-5
General Information
Revision date
2016-10-25
Product name
BAS206
1.2.1 Relevant identified uses
High Temperature Anti-Seize Compound
1.2.2. Uses advised against
None known
Manufacturer Name
Anti-Seize Technology
Emergency telephone
Number Infotrac 24/7
Icons in SDS
Company Information
company name
Pro Line Industrial Nexgen Brand
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H280, H317, H351, H370
Hazard statements
Code
Statements
H280
Contains gas under pressure; may explode if heated
Section 2
SECTION 2: Hazards identification
GHS / HAZCOM 2012 Classification
Skin Sensitizer Category 1 Carcinogen Category 2 Specific Target Organ Toxicity Single Exposure Category 1 (Inhalation)
Signal word
Danger
Hazard statements
H280 Gases under pressure. May explode if heated. P251 Pressurized container; Do not pierce or burn even after use. H317 May cause an allergic skin reaction H370 Causes damage to respiratory tract through inhalation H351 Suspected of causing cancer through inhalation
Prevention
P201 Obtain special instructions before use. P202 Do not handle until all safety precautions have been read and understood. P260 Do not breathe mist or vapor. P264 Wash thoroughly after handling. P270 Do not eat, drink or smoke when using this product. P272 Contaminated work clothing should not be allowed out of the workplace. P280 Wear protective gloves.
Response
P302+P352 IF ON SKIN: Wash with plenty of water. P333+P313 If skin irritation or rash occurs: Get medical attention. P362+P364 Take off contaminated clothing and wash it before reuse. P308+P311 IF exposed or concerned: Call a POISON CENTER or doctor. P308+P313 IF exposed or concerned: Get medical attention
Storage
P405 Store locked up. P412 Do not expose to temperatures exceeding 50°C, (122°F)
Disposal
P501 Dispose of contents in accordance with local, regional and national regulations.
2.3 Other hazards
None