Note: Ingredients listed on restricted chemical lists
EC/CAS
7732-18-5
Name of the chemical
Water, distilled, conductivity or of similar purity H2O
Concentration
70-90%
General Information
Revision date
2015-05-18
Product name
Iodide ISE Ionic Strength Adjuster Solution
1.2.1 Relevant identified uses
Buffers, Filling & Calibration Solutions
Emergency telephone
Bill Boyne 281-565-8818 x 133
Icons in SDS
Company Information
company name
Analytical Sensors & Instruments, Ltd
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H272, H319
Hazard statements
Code
Statements
H272
May intensify fire; oxidiser
Section 2
2.1 Classification of the substance or mixture
GHS03 Flame over circle Ox. Liq. 2 H272 May intensify fire; oxidizer. GHS07 Eye Irrit. 2A H319 Causes serious eye irritation.
2.2 Label elements
The product is classified and labeled according to the Globally Harmonized System (GHS).
Hazard pictograms
GHS03 GHS07
Signal word
Danger
Hazard statements
May intensify fire; oxidizer. Causes serious eye irritation.
Precautionary statements
Take any precaution to avoid mixing with combustibles. Keep away from heat. Keep/Store away from clothing/combustible materials. Wear protective gloves / eye protection / face protection. Wear eye protection / face protection. Wash thoroughly after handling. If in eyes: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. If eye irritation persists: Get medical advice/attention. In case of fire Use for extinction CO2, powder or water spray Dispose of contents/container in accordance with local/regional/national/international regulations. · Unknown acute toxicity: 29.8 percent of the mixture consists of ingredient(s) of unknown toxicity.
Classification system
NFPA ratings (scale 0 - 4) 1 Health = 1 1 Fire = 1 OX Reactivity = 1 The substance possesses oxidizing properties. · HMIS-ratings (scale 0 - 4) HEALTH 1 Health = 1 FIRE 1 Fire = 1 REACTIVITY 1 Reactivity = 1
2.3 Other hazards
None known