Labels – Generate Secondary Container Labels with just one click.
GHS07
Health risk rating 4
Safety risk rating 4
Environmental risk rating 5

Note: Ingredients listed on restricted chemical lists

EC/CAS

7440-47-3

Name of the chemical

Chromium; chromic acid and its salts

Concentration

N/A

EC/CAS

231-157-5/7440-50-8

Name of the chemical

Copper

Concentration

5-35

EC/CAS

231-096-4/7439-96-5

Name of the chemical

Manganese

Concentration

40-90

EC/CAS

231-107-2/7440-02-0

Name of the chemical

Nickel

Concentration

0-4

EC/CAS

231-130-8/7440-21-3

Name of the chemical

Silicon

Concentration

<1

Listed in

EC/CAS

215-607-8/1333-82-0

Name of the chemical

Chromium trioxide

Concentration

<1

EC/CAS

231-159-6

Name of the chemical

Copper (nano) [INCI] (11), Colloidal Copper (nano) [INCI] (11)

Concentration

0-4

EC/CAS

231-111-4

Name of the chemical

Nickel, Metall (790/2009)

Concentration

0-40

General Information

Product name

Type

Product name

Type

Identification on the label/Trade name

308, 308H, 308L, 308L HiSil, 309, 309{H), 309L, 309L HiSil, 310,316, ER316L, ER316L HiSil, 347, 410, 410NiMo, 317L, 630, 312, 2209

1.2.1 Relevant identified uses

GAS METAL ARC WELDING (GMAW) STAINLESS WIRE AND GAS TUNGSTEN ARC WELDING (GTAW) STAINLESS WIRE

1.2.2. Uses advised against

Use only as indicated for welding operations

Emergency telephone

+1 (412) 349-8431

Icons in SDS

GHS07

Company Information

company name

AMERICAN WIRE RESEARCH, INC

GHS Information

Signal word

No signal word required

Section 2

SECTION 2: Hazards identification

OSHA Hazards HAZARD CLASSIFICATION The products described in Section 1 is not classified as hazardous according to applicable GHS hazard classification criteria as required and defined in

2.2 Label elements

Hazard Symbol — No symbol required

Signal word

No signal word required

Hazard statements

Not applicable

Precautionary statements

Not Applicable

2.3 Other hazards

WARNING! - Avoid breathing welding fumes and gases, they may be dangerous to your health. Always use adequate ventilation. Always use appropriate personal protective equipment.

Principle Routes of Exposure

Respiratory System, Eyes and/or Skin ARC RAYS: The welding arc can injure eyes and burn skin. ELECTRIC SHOCK: Arc welding and associated processes can kill. See Section 8. FUMES AND GASES: Can be dangerous to your health. Welding fumes and gases cannot be classified simply. The composition and quantity of both are dependent upon the metal being welded, the process, procedures and electrodes used. Most fume ingredients are present as complex oxides and compounds and not as pure metals. When the electrode is consumed, the fume and gas decomposition products generated are different in percent and form from the ingredients listed in Section 3. Decomposition products of normal operation include those originating from the volatilization, reaction or oxidation of the materials shown in Section 3 of this Safety Data Sheet, plus those from the welding flux, the base metal and any coatings, etc. Monitor for the component materials identified in the list in Section 3. Fumes from the use of this product may contain complex oxides or compounds of the following elements and molecules: amorphous silica fume, chromium, copper, manganese and nickel. Other reasonably expected constituents of the fume would also include complex oxides of iron, silicon and molybdenum. Gaseous reaction products may include carbon monoxide and carbon dioxide. Ozone and nitrogen oxides may be formed by the radiation from the arc. Other conditions which also influence the composition and quantity of the fumes and gases to which workers may be exposed include: coatings on the metal being welded (such as paint, plating or galvanizing), the number of welders and the volume of the work area, the quality and amount of ventilation, the position of the welder's head with respect to the fume plume, as well as the presence of contaminants in the atmosphere (such as chlorinated hydrocarbon vapors from cleaning and degreasing activities). One recommended way to determine the composition and quantity of fumes and gases to which workers are exposed is to take an air sample inside the welder's helmet if worn or in the worker's breathing zone. See ANSI/AWS F1.1 and F1.3, available from the "American Welding Society", 8669 NW 36 Street, # 130, Miami, Florida 33166-6672, Phone: 800-443-9353 or 305-443-9353. Also, from AWS is F1.3 "Evaluating Contaminants in the Welding Environment - A Sampling Strategy Guide", which gives additional advice on sampling.

2.1 Classification of the substance or mixture

— The products described in Section 1 is not classified as hazardous according to applicable GHS hazard classification criteria as required and defined in OSHA Hazard Communication Standard (29 CFR Part 1910.1200).

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.