Note: Ingredients listed on restricted chemical lists
EC/CAS
29118-24-9
Name of the chemical
(E)-1,3,3,3-Tetrafluoro-1-propene
Concentration
3,3- 10-30
EC/CAS
9016-87-9
Name of the chemical
4,4'-Methylendiphenyldiisocyanat tech. (Polymeres) MDI, pMDI (in Form atembarer Aerosole, A-Fraktion)
Concentration
5-15
EC/CAS
231-783-9/7727-37-9
Name of the chemical
Nitrogen N2
Concentration
<1
General Information
Version
2.0
Revision date
2024-01-02
Product name
Euroroof PU Insulation Spray Adhesive
1.2.1 Relevant identified uses
Adhesive
supplier name
Alumasc Building Products Ltd
Emergency telephone
0344 892 0111, +44 17 4464 8400
Icons in SDS
Company Information
company name
Alumasc Building Products Ltd
e-mail address of the competent person responsible for the Safety Data Sheet
technical@alumascroofing.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H280, H315, H317, H319, H334, H351, H373
Hazard statements
Code
Statements
H280
Contains gas under pressure; may explode if heated
H315
Causes skin irritation
H317
May cause an allergic skin reaction
H319
Causes serious eye irritation
H334
May cause allergy or asthma symptoms or breathing difficulties if inhaled
H351
Suspected of causing cancer
H373
May cause damage to organs through prolonged or repeated exposure
Section 2
SECTION 2: Hazards identification
2.1 Classification of the substance or mixture
Considered a hazardous mixture according to Reg. (EC) No
2.2 Label elements
Hazard pictures
Signal word
Danger.
Hazard statements
H334 May cause allergy or asthma symptoms or breathing difficulties if inhaled. H373 May cause damage to organs through prolonged or repeated exposure. H315 Causes skin irritation. H319 Causes serious eye irritation. H280 Contains gas under pressure; may explode if heated.H319 Causes serious eye irritation. H317 May cause an allergic skin reaction. H351 Suspected of causing cancer.
Supplemental label elements
EUH044 Risk of explosion if heated under confinement. EUH204 Contains isocyanates. May produce an allergic reaction.
Prevention
P201 Obtain special instructions before use. P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P211 Do not spray on an open flame or other ignition source. P251 Do not pierce or burn, even after use. P260 Do not breathe gas. P271 Use only outdoors or in a well-ventilated area. P280 Wear protective gloves/protective clothing/eye protection/face protection. P284 [In case of inadequate ventilation] wear respiratory protection. P272 Contaminated work clothing should not be allowed out of the workplace.
Response
P304+P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing. P308+P313 IF exposed or concerned: Get medical advice/ attention. P342+P311 If experiencing respiratory symptoms: Call a POISON CENTER/doctor/ physician/first aider. P302+P352 IF ON SKIN: Wash with plenty of water and soap. P305+P351+P338IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P314 Get medical advice/attention if you feel unwell. P333+P313 If skin irritation or rash occurs: Get medical advice/attention. P337+P313 If eye irritation persists: Get medical advice/attention. P362+P364 Take off contaminated clothing and wash it before reuse.
Storage
P405 Store locked up. P410+P403 Protect from sunlight. Store in a well-ventilated place. Precautionary statements disposal P501 Dispose of contents/container to authorised hazardous or special waste collection point in accordance with any local regulation.
2.3 Other hazards
Polymeric Diphenylmethane Diisocyanate Listed in the Europe Regulation