Note: Ingredients listed on restricted chemical lists
EC/CAS
7732-18-5
Name of the chemical
Water, distilled, conductivity or of similar purity H2O
Concentration
15-40
EC/CAS
142844-00-6
Name of the chemical
Zirconia Aluminosilicate Refractory Ceramic Fibres
Concentration
20-50
EC/CAS
231-545-4/7631-86-9
Name of the chemical
Silver adsorbed on silicon dioxide
Concentration
0-40
EC/CAS
203-473-3/107-21-1
Name of the chemical
Ethane-1,2-diol
Concentration
0-6
General Information
Version
8
Revision date
2022-09-13
Product name
PYROFORM EXTENDER; PYROFORM E-Z FILL; MD-30
Substance name
Mixture containing Refractory Ceramic Fibers (RCF)/Alumino-Silicate Wools (ASW)
Chemical name
refractories, fibers, aluminosilicate
CAS No.
142844-00-6
REACH No
01-2119458050-50-000x
1.2.1 Relevant identified uses
Water-based, refractory mastic for “professional users” in industrial applications involving high temperature, heat treating, and molten metal processing
Emergency telephone
(800) 424-9300
Icons in SDS
Company Information
company name
Alkegen
e-mail address of the competent person responsible for the Safety Data Sheet
custservhowell@alkegen.com
GHS Information
Signal word
Warning
Hazard Codes
Hazard statements (CLP)
H351
Hazard statements
Code
Statements
H351
Suspected of causing cancer
Section 2
SECTION 2: Hazards identification
WHMIS 2015 Classification of the Substance or Mixture
Hazard pictograms
1
Signal word
Warning
Hazard statements
Suspected of causing cancer by inhalation.
Precautionary statements
Do not handle until all safety instructions have been read and understood. Use respiratory protection as required; see section 8 of the Safety Data Sheet If concerned about exposure, get medical advice. Store in a manner to minimize airborne dust. Dispose of waste in accordance with local, state and federal regulations.
2.3 Other hazards
Mild mechanical irritation to skin, eyes, and upper respiratory system may result from exposure. These effects are usually temporary.
2.1 Classification of the substance or mixture
The U.S. Occupational Safety and Health Administration (OSHA) Hazard Communication Standard (HCS) 2012 indicates that IARC group 2B corresponds to OSHA HCS 2012 Category 2 carcinogen classification (see, e.g., §1910.1200, Appendix F, Part D). Under OSHA HCS 2012, RCF is classified as a Category 2 carcinogen. Canada: WHMIS 2015 Carcinogenicity Category 2