Note: Ingredients listed on restricted chemical lists
EC/CAS
7440-37-1
Name of the chemical
Argon Ar
Concentration
N/A
EC/CAS
630-08-0
Name of the chemical
Kohlenmonoxid
Concentration
N/A
General Information
Revision date
2015-08-28
Product name
Methane (0.00001% - 5.00%), Carbon Monoxide (1.00% - 7.50%) in Argon
Icons in SDS
Company Information
company name
Air Liquide
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H280, H360, H372
Hazard statements
Code
Statements
H280
Contains gas under pressure; may explode if heated
H360
May damage fertility or the unborn child
H372
Causes damage to organs through prolonged or repeated exposure
Section 2
Classification (GHS-US)
Compressed gas H280 - Contains gas under pressure; may explode if heated Repr. 1A H360 - May damage fertility or the unborn child STOT RE 1 H372 - Causes damage to organs (central nervous system) through prolonged or repeated exposure
Hazard statements
see section 16 : H280 - Contains gas under pressure; may explode if heated H360 - May damage fertility or the unborn child H372 - Causes damage to organs (central nervous system) through prolonged or repeated exposure CGA-HG10 - Asphyxiating even with adequate oxygen
2.2 Label elements
GHS-US labeling
Hazard pictograms
GHS04 GHS08
Signal word
Danger
Precautionary statements
P202 - Do not handle until all safety precautions have been read and understood P260 - Do not breathe gas P271 - Use only outdoors or in a well-ventilated area P280 - Wear eye protection, face protection, protective gloves, protective clothing P304+P340 - If inhaled: Remove person to fresh air and keep comfortable for breathing P308+P313 - If exposed or concerned: Get medical advice/attention P403 - Store in a well-ventilated place P405 - Store locked up P501 - Dispose of contents/container in accordance with local/regional/national/international regulations CGA-PG02 - Protect from sunlight when ambient temperature exceeds 52°C (125°F) CGA-PG05 - Use a back flow preventive device in the piping CGA-PG06 - Close valve after each use and when empty CGA-PG10 - Use only with equipment rated for cylinder pressure CGA-PG14 - Approach suspected leak area with caution CGA-PG21 - Open valve slowly 08/28/2015 EN (English US)
Other hazards which do not result in classification
This product contains a chemical asphyxiant. 2.4.
Ingredient(s) with unknown acute toxicity